Cleaning and care
Once the descaling solution has been drawn into the appliance
–"Activation phase" will appear in the display. The activation phase takes approx. 60 minutes.
–the time left for the activation phase will be shown counting down in the display.
The system will take in more liquid at approximately five minute intervals. You will hear the noise of the pump for a moment or so.
The oven lighting and the cooling fan will remain on during descaling.
The steam injection system will need to be cleaned at the end of the descaling process to remove all traces of descaling solution.
Prompts to do this will appear in the display.
Cleaning is carried out by flushing approx. 1 litre of mains tap water through the system. The water is collected in the universal tray. This process is repeated three times.
^Take the universal tray out of the oven and empty it. Place the tray back in the oven again at the top shelf level.
^Unclip the plastic tube from the container. Rinse out the container and fill with approx. one litre of mains tap water. Place the container in the oven, insert the plastic tube and secure it to the container with the clip.
^Start the first rinse.
^Repeat twice.
Empty the universal tray before the second and third rinse.
After the third rinse, residual water will need to be evaporated from the steam injection system.
Before proceeding, remove the plastic tube and the container from the oven.
The oven will heat up to "Evaporate residual moisture". You can follow the time in the display.
Allow the oven to cool down before cleaning by hand. Danger of burning.
^Remove the universal tray and empty it. Clean the oven interior to remove any condensation and descaling agent residue.
Leave the oven door open until the oven interior is completely dry.
68