Vulcan-Hart 60(S,C)(S,C), 72(S,C)(S,C), 48(S,C) Leveling, GAS Pressure Regulator, GAS Connections

Page 6

If disconnection of the restraint is necessary, turn off the gas supply before disconnection. Reconnect this restraint prior to turning the gas supply on and returning the range to its installation position.

If the range is installed on casters and is moved for any reason, it is recommended that the range be re-leveled front to back and side to side for even baking.

LEVELING

To level the range, place a carpenter's level on the range top and check leveling of the unit side to side and front to rear. Achieve leveling by turning each foot section of the unit's leg as needed. Turning the foot in a counter clockwise direction will increase height and clockwise will decrease.

GAS PRESSURE REGULATOR

A preset gas pressure regulator and street elbow is shipped with the range. This regulator must be installed by an authorized service person before the unit is placed into operation. See full unit data plate located on the rear of the range, or the secondary data plate, riveted to the kick panel, for pressure regulator setting information. If a manometer is being used, utilizing one of the available pressure taps in the manifold, the manifold pressure with one burner on should be ± 0.3" W.C. of the value indicated on the rating plate.

1.Locate the gas connection pipe protruding through the back of the unit.

2.Cover the pipe threads with pipe joint compound resistant to propane gases.

3.Screw the regulator onto the pipe hand tight with flow direction arrow pointing towards the back of the unit and the regulator adjustment in the up right position.

4.With a pipe wrench, tighten the regulator securely in the upright position. (The regulator is preset and should not require any additional adjustments.) The pressure regulator must be mounted horizontally to ensure the proper preset outlet pressure. If mounted in any other direction, the outlet pressure must be rechecked and possibly reset. A leak limiter is supplied with every regulator to allow excess gas pressure to escape. Do not obstruct the limiter or the gas regulator, as obstruction may cause the regulator to malfunction.

GAS CONNECTIONS

All gas supply connections and any pipe joint compound used must be resistant to the action of propane gases.

Prior to lighting, check all joints in the gas supply line for leaks. Use soap and water solution. Do not use an open flame.

After piping has been checked for leaks, all piping receiving gas should be fully purged to remove air.

TESTING THE GAS SUPPLY SYSTEM

When test pressures exceed ½ psig (3.45 kPa), the range and its individual shutoff valve must be disconnected from the gas supply piping system.

When test pressures are ½ psig (3.45 kPa) or less, the range must be isolated from the gas supply system by closing its individual manual shutoff valve.

- 6 -

Image 6
Contents Vulcan Endurance Series Gas Restaurant Ranges Retain this Manual for Future USEImportant for Your Safety For Your SafetyAccessories Optional Field Installable AccessoriesInstallation DescriptionUnited States of America Installation Codes and StandardsLocation CanadaLEG/CASTER Assembly Range Series Legs to Install Casters to InstallGAS Pressure Regulator Testing the GAS Supply SystemLeveling GAS ConnectionsElectrical Connections OperationFlue Connections ControlsGriddles Before First USEOvens Lighting and Shutting Down Pilots TOP SectionsThermostatic Griddle Operating Suggestions Loading and Unloading the OvenCleaning Daily CleaningOpen Top Stainless Steel Maintenance & AdjustmentsExterior Cleaning LubricationOven Problem Causes / Corrections TroubleshootingService and Parts Information Precautions TOP Burner Operation Problem Causes / CorrectionsForm F38201 Rev. a Remarques Dépannage Possibles Problème Cuisson DE Surface LA DE BrûleurProblème Four Lubrification Rechange DE Pièces ET L’ENTRETIEN DE ServiceRéglages ET Entretien Inoxydable AcierFrire à plaque la de Surface Conventionnel four un dans Cuisson Nettoyage’appareil de nettoyage le avant gaz le Éteindre Découverts Brûleurs Fonctionnement DE SuggestionsPermanente veilleuse d’une Cuisson DE Surfaces Veilleuses DES Extinction ET Allumage Utilisation Première UNE AvantCommandes FonctionnementGAZ DE Pression DE Régulateur ’ÉVACUATION ConduitGAZ DU Branchement NivelageFigure la à qu’illustrés tels percés Roulettes OU Pattes DES AssemblageCanada Au Normes ET D’INSTALLATION CodesEmplacement Unis-États AuxGénéralitês DéballageSécurité DE Mesure Importantes Sécurité DE Mesures’EMPLOI Mode ET D’INSTALLATION Mode