Southbend STRE-3D owner manual Location of Connections and Vents, Drain Connection

Page 15

STRATOSTEAM COUNTERTOP STEAMER

INSTALLATION

Figure 6

Location of Connections and Vents

Pressure-Relief Vent (do not obstruct)

Electric Cable Entry Hole (connection is made inside)

Water Inlet Connection (1/4" compression)

Drain Box Emergency Overflow Vent (do not obstruct)

Water Drain Connection (1" NPT female)

STEP 3: DRAIN CONNECTION

The drain outlet is located on the back of the steamer, as shown in Figure 6. The drain connector on the steamer is 1" (32 mm) NPT female.

Position the steamer near, but not on top of, an open floor drain. DO NOT directly plumb the steamer unless you also install an “open funnel” downstream of this connection in the drain system. Make the drain line from the steamer to the air gap above the “open funnel” as short as possible. There should be no horizontal piping between the steamer and the air gap above the open funnel. The open funnel is intended to eliminate any water from entering the steamer because of a blocked drain, and it also prevents any back pressure within the steamer cavity. Any connection that allows the build-up of back pressure in the steamer (such as a reduction in pipe size to a line smaller than 1", or more than one 90-degree angle in the line prior to the open funnel drain discharge point) may cause personal or property damage and will therefore void the warranty. The steamer is a pressureless, free-venting steam cooker and will not operate properly unless the drain line is short, at a steep angle, and open! See Figure 7 on the next page.

OWNERS MANUAL 1185184

PAGE 15 OF 48

Image 15
Contents StratoSteam Safety Precautions Location of Serial Plates IntroductionSpecifications DimensionsClearances Right Side View DimensionsElectrical Requirements Water RequirementsDrain Requirements Operation Troubleshooting by OperatorOperation StartupCooking Tips ControlsSuggested Cooking Times STAINLESS-STEEL Surfaces Cleaning & MaintenanceDaily Cleaning and Maintenance Periodic DE-LIMING AS NeededStratosteam Countertop Steamer Cleaning & Maintenance Unpacking InstallationAttach Legs Attach LegsStacking TWO Steamers Installation on CountertopAttach to Countertop Mounting on Cabinet BaseDrain Connection Location of Connections and VentsWater Drain Water ConnectionWater Connection Electrical Connection Electrical ConnectionCheck the Installation SHUT-DOWN and WIPE-CLEAN SteamerCheck Steamer Operation Troubleshooting FLOWCHARTS, PROCEDURES, and Wiring Diagrams ServiceHOW the Steamer Operates How the Steamer Operates Disconnect Power AT Circuit Breaker Steamer Not Heating Up, Power Light Is Not LitCheck that water-supply pressure is adequate Buzzer Does Not Come On When Timer Runs Out Heating Cartridge Check at Contactor Disconnect Power AT Circuit BreakerPower Switch Check Contactor Check Timer and Buzzer Check Door Switch Check High-Limit Thermostats Check Water-Level-Control Sensor Check Water Solenoid Check Wiring Diagram for 208/220/240 Volt Models Wiring Diagram for 480 Volt Models Parts Parts DiagramStructural Parts See parts list on previous Door Assembly Parts Door Switch Parts Control Panel Parts Heating Cartridges, Thermostats, and Contactor Parts Water Train Parts Water-Train Parts Cabinet Base Parts Cabinet-Base Parts Stratosteam Countertop Steamer Stratosteam Countertop Steamer StratoSteam Countertop Steamer Models STRE-3D and STRE-5D