STRATOSTEAM COUNTERTOP STEAMER | INSTALLATION |
STEP 5: ELECTRICAL CONNECTION
The electric connection is made to the contactor, which is located inside the service compartment on the right side of the steamer. The right side panel must be removed to gain access to the contactor. A hole on the rear of each steamer is provided for a 3/4" conduit fitting (solid or flex). An electric cable support bracket and clamp are located inside of the service compartment, to the right and above the contactor (see Figure 8).
Be sure that the input voltage and number of phases matches the requirement stated on the serial plate. The steamer is factory wired per customer order. A wiring diagram is attached to the inside of the right side panel of the steamer.
WARNING
A POSITIVE GROUND CONNECTION IS ESSENTIAL. DO NOT ALLOW ANY TAMPERING OR ADJUSTMENT OF ANY CONTROL OR WIRING. THE STEAMER IS FACTORY SET. ADJUSTING ANY INTERNAL COMPONENT CAN VOID THE WARRANTY.
THIS STEAMER REQUIRES A KIT TO BE FIELD CONVERTED FROM
For
Make the electrical ground connection to the ground lug located at the top
Figure 9 |
|
|
|
|
Electrical Connection |
|
|
| |
|
| Contactor | Cable Support |
|
|
| Bracket |
| |
|
|
| (with clamp) |
|
|
|
| Hole for |
|
|
|
| Cable Conduit |
|
|
|
| (with fitting) |
|
Connections | Connections | |||
to Contactor for | to Contactor for | |||
L1 | L2 | L3 | L1 | L2 |
|
| Top of | Top of |
|
|
| Steamer | Steamer |
|
|
| OWNER’S MANUAL 1185184 |
| PAGE 17 OF 48 |