STRATOSTEAM COUNTERTOP STEAMER | SERVICE |
Figure 14
Heating Cartridge Check (at Contactor)
L1 | L2 | L3 | Top of |
|
|
| |
|
|
| Steamer |
Ohms
A B C
1.DISCONNECT POWER AT CIRCUIT BREAKER.
2.Turn Control Lever to OFF.
3.Remove right side panel of steamer.
4.DO NOT DISCONNECT
5.Using a multimeter, check the resistance across contactor terminals as specified in the following table:
Serial- |
|
| Model |
|
| Model |
| ||||
| Allowable Resistance (Ohms) |
| Allowable Resistance (Ohms) |
| |||||||
Plate |
|
|
| ||||||||
|
|
|
|
| |||||||
Voltage |
|
|
|
|
| ||||||
|
|
| |||||||||
208 | 10 | to 12 | 14 | to 16 |
| 5 to 6 | 8 to 10 | 11 | to 13 |
| 4 to 5 |
220 | 12 | to 13 | 15 | to 18 |
| 6 to 7 | 9 to 11 | 13 | to 15 |
| 5 to 6 |
240 | 14 | to 16 | 18 | to 21 |
| 7 to 9 | 11 to 13 | 15 | to 17 |
| 6 to 7 |
480 | 55 | to 64 | 73 | to 85 |
| 29 to 34 | 45 to 52 | 60 | to 70 |
| 24 to 28 |
6.If the measured resistance at the contactor is not in the specified range, disconnect all the heating cartridges from the contactor. Measure the resistance across the leads each cartridge. Replace any cartridge that shows either an open or short circuit.
OWNER’S MANUAL 1185184 | PAGE 25 OF 48 |