Southbend STRE-3D owner manual Contactor Check

Page 27

STRATOSTEAM COUNTERTOP STEAMER

 

SERVICE

Figure 16

 

 

 

Contactor Check

 

 

 

Top of

 

 

 

Steamer

 

 

 

L1

L2

L3

Ohms

 

Actuator

 

 

No Continuity

Button

 

 

 

 

 

A

B

C

View Looking Down

 

 

 

 

 

 

Behind Contactor

1.DISCONNECT POWER AT CIRCUIT BREAKER.

2.Remove right side panel.

3.Depress actuator on top of contactor. Actuator should travel freely and spring back when released.

4.Check for continuity between contacts L1 and A as shown above. There should be no continuity.

5.Repeat Step 4 for contacts L2 and B and for contacts L3 and C.

6.Remove wires B3 and B9 from contactor coil.

7.Place test leads on contactor coil terminals as shown in “View Looking Down” shown above and check resistance

8.If resistance is not in the range 350 to 425 ohms, replace contactor.

9.Reconnect all wires.

OWNERS MANUAL 1185184

PAGE 27 OF 48

Image 27
Contents StratoSteam Safety Precautions Location of Serial Plates IntroductionSpecifications DimensionsClearances Right Side View DimensionsElectrical Requirements Water RequirementsDrain Requirements Operation Troubleshooting by OperatorOperation StartupCooking Tips ControlsSuggested Cooking Times STAINLESS-STEEL Surfaces Cleaning & MaintenanceDaily Cleaning and Maintenance Periodic DE-LIMING AS NeededStratosteam Countertop Steamer Cleaning & Maintenance Unpacking InstallationAttach Legs Attach LegsStacking TWO Steamers Installation on CountertopAttach to Countertop Mounting on Cabinet BaseDrain Connection Location of Connections and VentsWater Drain Water ConnectionWater Connection Electrical Connection Electrical ConnectionCheck the Installation SHUT-DOWN and WIPE-CLEAN SteamerCheck Steamer Operation Troubleshooting FLOWCHARTS, PROCEDURES, and Wiring Diagrams ServiceHOW the Steamer Operates How the Steamer Operates Disconnect Power AT Circuit Breaker Steamer Not Heating Up, Power Light Is Not LitCheck that water-supply pressure is adequate Buzzer Does Not Come On When Timer Runs Out Heating Cartridge Check at Contactor Disconnect Power AT Circuit BreakerPower Switch Check Contactor Check Timer and Buzzer Check Door Switch Check High-Limit Thermostats Check Water-Level-Control Sensor Check Water Solenoid Check Wiring Diagram for 208/220/240 Volt Models Wiring Diagram for 480 Volt Models Parts Parts DiagramStructural Parts See parts list on previous Door Assembly Parts Door Switch Parts Control Panel Parts Heating Cartridges, Thermostats, and Contactor Parts Water Train Parts Water-Train Parts Cabinet Base Parts Cabinet-Base Parts Stratosteam Countertop Steamer Stratosteam Countertop Steamer StratoSteam Countertop Steamer Models STRE-3D and STRE-5D