Southbend STRE-3D owner manual Timer and Buzzer Check

Page 28

SERVICE

STRATOSTEAM COUNTERTOP STEAMER

Figure 17

Timer and Buzzer Check

Continuity

1

3

Timer

Ohms

Buzzer

Inside of Control Panel

1.DISCONNECT POWER AT CIRCUIT BREAKER.

2.Remove right side panel.

3.Set timer for one minute and allow to time out. If timer does not run, then replace timer.

4.Disconnect from the timer the wire that leads to the buzzer.

5.Disconnect connector PL1 to separate the other buzzer lead wire from the wiring harness.

6.Place test leads between positions 1 and 3 on the timer (as shown above).

7.Check for continuity when the timer has run down (so the buzzer should be on). If no continuity, replace timer.

8.Disconnect other lead wire from buzzer. Place test leads in terminals of buzzer lead wires (as shown above).

9.Check that resistance is approximately 3.4 Kohms. If it is not, replace the buzzer.

10.Reconnect wires.

PAGE 28 OF 48

OWNERS MANUAL 1185184

Image 28
Contents StratoSteam Safety Precautions Introduction Location of Serial PlatesDimensions SpecificationsClearances Dimensions Right Side ViewWater Requirements Electrical RequirementsDrain Requirements Troubleshooting by Operator OperationStartup OperationControls Cooking TipsSuggested Cooking Times Cleaning & Maintenance Daily Cleaning and MaintenancePeriodic DE-LIMING AS Needed STAINLESS-STEEL SurfacesStratosteam Countertop Steamer Cleaning & Maintenance Installation UnpackingAttach Legs Attach LegsInstallation on Countertop Attach to CountertopMounting on Cabinet Base Stacking TWO SteamersLocation of Connections and Vents Drain ConnectionWater Connection Water DrainWater Connection Electrical Connection Electrical ConnectionSHUT-DOWN and WIPE-CLEAN Steamer Check the InstallationCheck Steamer Operation Service Troubleshooting FLOWCHARTS, PROCEDURES, and Wiring DiagramsHOW the Steamer Operates How the Steamer Operates Steamer Not Heating Up, Power Light Is Not Lit Disconnect Power AT Circuit BreakerCheck that water-supply pressure is adequate Buzzer Does Not Come On When Timer Runs Out Disconnect Power AT Circuit Breaker Heating Cartridge Check at ContactorPower Switch Check Contactor Check Timer and Buzzer Check Door Switch Check High-Limit Thermostats Check Water-Level-Control Sensor Check Water Solenoid Check Wiring Diagram for 208/220/240 Volt Models Wiring Diagram for 480 Volt Models Parts Diagram PartsStructural Parts See parts list on previous Door Assembly Parts Door Switch Parts Control Panel Parts Heating Cartridges, Thermostats, and Contactor Parts Water Train Parts Water-Train Parts Cabinet Base Parts Cabinet-Base Parts Stratosteam Countertop Steamer Stratosteam Countertop Steamer StratoSteam Countertop Steamer Models STRE-3D and STRE-5D