SERVICE | STRATOSTEAM COUNTERTOP STEAMER |
Figure 11
Steamer Not Heating Up, “Power” Light Is Not Lit
Steamer not heating up, “Power” light not lit.
DISCONNECT POWER AT CIRCUIT BREAKER
Remove right side panel for access.
Reconnect power at circuit breaker.
Turn lever to “ON” position and close door (to actuate door switch).
Check voltage between terminals L1 and L3 on contactor
(see page 27).
| Is measured |
| |
No | Yes | ||
voltage 208, 220, or 240 | |||
| volts? |
| |
|
|
DISCONNECT POWER AT CIRCUIT BREAKER
Check resistance between
as described on page 25.
Test operation of power switch (see page 26). Replace if
necessary. If power switch is OK, replace “Power” light and follow
procedure on page 23.
| Is measured resistance |
| |
No | Yes | ||
in the range specified on | |||
| page 25? |
|
Disconnect all the heating
cartridges from the contactor. Measure the resistance across the leads each cartridge. Replace any cartridge that shows either an open or short circuit.
Check main fuses (480V
models only) and replace as
needed.
PAGE 22 OF 48 | OWNER’S MANUAL 1185184 |