Southbend STRE-3D owner manual Water Solenoid Check

Page 32

SERVICE

STRATOSTEAM COUNTERTOP STEAMER

Figure 21

 

Water Solenoid Check

 

 

Ohms

 

Volts

1.DISCONNECT POWER AT CIRCUIT BREAKER.

2.Remove right side panel.

3.Disconnect wires B6 and B7 from water solenoid lead wires.

4.Place test probes into water solenoid lead wires as shown above.

5.Resistance should be approximately 800 ohms. Replace if necessary.

6.Apply waterline pressure to water inlet. Water should not leak out of the compression fittings. If necessary, replace water solenoid. Check to see that water is slowly running into the cooking cavity.

7.Reconnect solenoid lead wires and reconnect power to steamer. When power is turned on with the steamer cool, the solenoid should “click.” If no click is heard, test for 200 to 240 volts on wires B6 and B7. If 200 to 240 volts is present and the water solenoid does not click, replace water solenoid.

PAGE 32 OF 48

OWNERS MANUAL 1185184

Image 32
Contents StratoSteam Safety Precautions Introduction Location of Serial PlatesClearances SpecificationsDimensions Dimensions Right Side ViewDrain Requirements Electrical RequirementsWater Requirements Troubleshooting by Operator OperationStartup OperationControls Cooking TipsSuggested Cooking Times Cleaning & Maintenance Daily Cleaning and MaintenancePeriodic DE-LIMING AS Needed STAINLESS-STEEL SurfacesStratosteam Countertop Steamer Cleaning & Maintenance Installation UnpackingAttach Legs Attach LegsInstallation on Countertop Attach to CountertopMounting on Cabinet Base Stacking TWO SteamersLocation of Connections and Vents Drain ConnectionWater Connection Water DrainWater Connection Electrical Connection Electrical ConnectionCheck Steamer Operation Check the InstallationSHUT-DOWN and WIPE-CLEAN Steamer Service Troubleshooting FLOWCHARTS, PROCEDURES, and Wiring DiagramsHOW the Steamer Operates How the Steamer Operates Steamer Not Heating Up, Power Light Is Not Lit Disconnect Power AT Circuit BreakerCheck that water-supply pressure is adequate Buzzer Does Not Come On When Timer Runs Out Disconnect Power AT Circuit Breaker Heating Cartridge Check at ContactorPower Switch Check Contactor Check Timer and Buzzer Check Door Switch Check High-Limit Thermostats Check Water-Level-Control Sensor Check Water Solenoid Check Wiring Diagram for 208/220/240 Volt Models Wiring Diagram for 480 Volt Models Parts Diagram PartsStructural Parts See parts list on previous Door Assembly Parts Door Switch Parts Control Panel Parts Heating Cartridges, Thermostats, and Contactor Parts Water Train Parts Water-Train Parts Cabinet Base Parts Cabinet-Base Parts Stratosteam Countertop Steamer Stratosteam Countertop Steamer StratoSteam Countertop Steamer Models STRE-3D and STRE-5D