Southbend STRE-3D owner manual Heating Cartridges, Thermostats, and Contactor Parts

Page 41

STRATOSTEAM COUNTERTOP STEAMER

SERVICE

Figure 28

Heating Cartridges, Thermostats, and Contactor Parts

 

 

 

 

 

 

3

 

 

 

 

4

 

 

 

 

 

1

 

 

 

 

 

2

 

Key

Part Number

Quantity*

Description

 

3D

5D

 

 

 

 

 

1

1181032

1

1

CONTACTOR 208-240V

 

2

1181501

6

-

HEATER CARTRIDGE, 208V 60HZ (for Model STRE-3D)

 

 

1181771

-

6

HEATER CARTRIDGE, 208V 60HZ (for Model STRE-5D)

 

 

1181502

6

-

HEATER CARTRIDGE, 220V 50/60HZ (for Model STRE-3D)

 

 

1181772

-

6

HEATER CARTRIDGE, 220V 50/60HZ (for Model STRE-5D)

 

 

1181503

6

-

HEATER CARTRIDGE, 240V 60HZ (for Model STRE-3D)

 

 

1181773

-

6

HEATER CARTRIDGE, 240V 60HZ (for Model STRE-5D)

 

 

1181504

6

-

HEATER CARTRIDGE, 480V 60HZ (for Model STRE-3D)

 

 

1181774

-

6

HEATER CARTRIDGE, 480V 60HZ (for Model STRE-5D)

 

3

1185197

3

3

HIGH TEMP LIMIT THERMOSTAT

 

4

1185177

1

1

CONTROL THERMOSTAT

 

*

Quantity of part used may depend on model (STRE-3D or SRTE-5D).

 

 

 

 

 

OWNERS MANUAL 1185184

PAGE 41 OF 48

Image 41
Contents StratoSteam Safety Precautions Location of Serial Plates IntroductionClearances SpecificationsDimensions Right Side View DimensionsDrain Requirements Electrical RequirementsWater Requirements Operation Troubleshooting by OperatorStartup OperationCooking Tips ControlsSuggested Cooking Times Daily Cleaning and Maintenance Cleaning & MaintenancePeriodic DE-LIMING AS Needed STAINLESS-STEEL SurfacesStratosteam Countertop Steamer Cleaning & Maintenance Unpacking InstallationAttach Legs Attach LegsAttach to Countertop Installation on CountertopMounting on Cabinet Base Stacking TWO SteamersDrain Connection Location of Connections and VentsWater Connection Water DrainWater Connection Electrical Connection Electrical ConnectionCheck Steamer Operation Check the InstallationSHUT-DOWN and WIPE-CLEAN Steamer Troubleshooting FLOWCHARTS, PROCEDURES, and Wiring Diagrams ServiceHOW the Steamer Operates How the Steamer Operates Disconnect Power AT Circuit Breaker Steamer Not Heating Up, Power Light Is Not LitCheck that water-supply pressure is adequate Buzzer Does Not Come On When Timer Runs Out Heating Cartridge Check at Contactor Disconnect Power AT Circuit BreakerPower Switch Check Contactor Check Timer and Buzzer Check Door Switch Check High-Limit Thermostats Check Water-Level-Control Sensor Check Water Solenoid Check Wiring Diagram for 208/220/240 Volt Models Wiring Diagram for 480 Volt Models Parts Parts DiagramStructural Parts See parts list on previous Door Assembly Parts Door Switch Parts Control Panel Parts Heating Cartridges, Thermostats, and Contactor Parts Water Train Parts Water-Train Parts Cabinet Base Parts Cabinet-Base Parts Stratosteam Countertop Steamer Stratosteam Countertop Steamer StratoSteam Countertop Steamer Models STRE-3D and STRE-5D