STRATOSTEAM COUNTERTOP STEAMEROPERATION
OPERATION
NOTICE: WATER SPECIFICATION
To meet warranty requirements, supply water must meet the following specification:
Total Dissolved Solids (TDS) | 60 PPM or less |
Hardness | 2 Grains (35 PPM) or less |
pH Factor | 7.0 to 7.5 |
STARTUP
Turn control lever to “ON” position (see Figure 3). The steamer will fill automatically and be ready for cooking in about four minutes.
OPERATION
CAUTION
HOT STEAM WILL ESCAPE WHEN DOOR IS BEING OPENED. TO PREVENT BURNS KEEP HANDS AND FACE AWAY FROM STEAM.
When turned ON, the steamer operates continuously. To save water and electricity, turn the control lever to OFF when the steamer is not in use.
Suggested cooking times for various foods are shown in the table in the following section. Pan specifications are shown on page 4.
The door may be opened or closed at any time. The steamer temporarily shuts off while the door is open. Timer can be used as a reminder to the operator. The timer does NOT turn the steamer on or off!
SHUTDOWN
Turn lever to the “OFF” position. The water in the bottom of the cavity will automatically drain.
TROUBLESHOOTING BY OPERATOR
The following table lists the possible causes and solutions of problems that may occur during operation.
Problem | Possible Causes and Solutions |
|
|
Steamer does not heat up at all.
–Electric power is shut off. Turn on power.
–Water supply is shut off. Turn on water.
–Not enough water is entering steamer. Check water supply.
–Lime
–If water is OK and there is little lime
Steamer does heat up, but does not produce enough steam.
–Door is open or ajar. Close steamer door completely.
–Lime
–Not enough water. Check water supply.
Steamer does not drain correctly.
–Clogged drain on inside of steamer cavity. Check and clear.
–Clogged drain outside of steamer. Check and clear.
OWNER’S MANUAL 1185184 | PAGE 7 OF 48 |