STRATOSTEAM COUNTERTOP STEAMEROPERATION

OPERATION

NOTICE: WATER SPECIFICATION

To meet warranty requirements, supply water must meet the following specification:

Total Dissolved Solids (TDS)

60 PPM or less

Hardness

2 Grains (35 PPM) or less

pH Factor

7.0 to 7.5

STARTUP

Turn control lever to “ON” position (see Figure 3). The steamer will fill automatically and be ready for cooking in about four minutes.

OPERATION

CAUTION

HOT STEAM WILL ESCAPE WHEN DOOR IS BEING OPENED. TO PREVENT BURNS KEEP HANDS AND FACE AWAY FROM STEAM.

When turned ON, the steamer operates continuously. To save water and electricity, turn the control lever to OFF when the steamer is not in use.

Suggested cooking times for various foods are shown in the table in the following section. Pan specifications are shown on page 4.

The door may be opened or closed at any time. The steamer temporarily shuts off while the door is open. Timer can be used as a reminder to the operator. The timer does NOT turn the steamer on or off!

SHUTDOWN

Turn lever to the “OFF” position. The water in the bottom of the cavity will automatically drain.

TROUBLESHOOTING BY OPERATOR

The following table lists the possible causes and solutions of problems that may occur during operation.

Problem

Possible Causes and Solutions

 

 

Steamer does not heat up at all.

Electric power is shut off. Turn on power.

Water supply is shut off. Turn on water.

Not enough water is entering steamer. Check water supply.

Lime build-up. De-lime steamer cavity (see page 10).

If water is OK and there is little lime build-up, call repair service.

Steamer does heat up, but does not produce enough steam.

Door is open or ajar. Close steamer door completely.

Lime build-up. De-lime steamer cavity (see page 10).

Not enough water. Check water supply.

Steamer does not drain correctly.

Clogged drain on inside of steamer cavity. Check and clear.

Clogged drain outside of steamer. Check and clear.

OWNERS MANUAL 1185184

PAGE 7 OF 48

Image 7
Contents StratoSteam Safety Precautions Location of Serial Plates IntroductionDimensions SpecificationsClearances Right Side View DimensionsWater Requirements Electrical RequirementsDrain Requirements Operation Troubleshooting by OperatorOperation StartupCooking Tips ControlsSuggested Cooking Times STAINLESS-STEEL Surfaces Cleaning & MaintenanceDaily Cleaning and Maintenance Periodic DE-LIMING AS NeededStratosteam Countertop Steamer Cleaning & Maintenance Unpacking InstallationAttach Legs Attach LegsStacking TWO Steamers Installation on CountertopAttach to Countertop Mounting on Cabinet BaseDrain Connection Location of Connections and VentsWater Connection Water DrainWater Connection Electrical Connection Electrical ConnectionSHUT-DOWN and WIPE-CLEAN Steamer Check the InstallationCheck Steamer Operation Troubleshooting FLOWCHARTS, PROCEDURES, and Wiring Diagrams ServiceHOW the Steamer Operates How the Steamer Operates Disconnect Power AT Circuit Breaker Steamer Not Heating Up, Power Light Is Not LitCheck that water-supply pressure is adequate Buzzer Does Not Come On When Timer Runs Out Heating Cartridge Check at Contactor Disconnect Power AT Circuit BreakerPower Switch Check Contactor Check Timer and Buzzer Check Door Switch Check High-Limit Thermostats Check Water-Level-Control Sensor Check Water Solenoid Check Wiring Diagram for 208/220/240 Volt Models Wiring Diagram for 480 Volt Models Parts Parts DiagramStructural Parts See parts list on previous Door Assembly Parts Door Switch Parts Control Panel Parts Heating Cartridges, Thermostats, and Contactor Parts Water Train Parts Water-Train Parts Cabinet Base Parts Cabinet-Base Parts Stratosteam Countertop Steamer Stratosteam Countertop Steamer StratoSteam Countertop Steamer Models STRE-3D and STRE-5D