SERVICE | STRATOSTEAM COUNTERTOP STEAMER |
HOW THE STEAMER OPERATES
Compared to steam cookers that have complicated boilers, a StratoSteam steamer is a very simple machine. The heating cartridges are integrated into the bottom plate of the cooking cavity, and begin to heat immediately as soon as the steamer is turned on. As water flows into the cooking cavity it covers the heated bottom plate and is converted to steam. There is no pressure in the steamer. From a cold start the steamer will heat up to cooking temperature in about 4 minutes.
The internal components of the steamer are shown in Figure 10 on the next page.
Turning the control lever to ON mechanically actuates the power switch, and so turns on power to the rest of the circuitry. The “Power” indicator light comes on. Turning the control lever to ON also mechanically closes the cooking- cavity drain valve.
The heating cartridges are controlled by a contactor. The contactor is energized (turning on the heating cartridges) if
(1)the door is shut (as sensed by the door switch), (2) the steamer is not overheated (as sensed by the
The flow of water into the cooking cavity is controlled by the water solenoid, which is energized (turning on the water) when the control lever is turned to ON and the door is shut. Hence, when cooking, water flows continuously into the cooking cavity.
If a
During operation, excess heated water flows into the drain box where it mixes with a small stream of cold water that is continuously supplied to the drain box (to prevent the draining water from being too hot for the plumbing pipes). Water drains from the drain box out the water drain on the rear of the steamer. If the drain is clogged, water
Any excess steam is vented out the
The dial thermometer on the control panel is connected by a capillary tube to a sensor bulb located in the pressure- relief vent. The thermometer does not affect the operation of the steamer.
A mechanical timer activates a buzzer when the timer times out. The timer does not affect anything else!
When the control valve is turned to OFF, power to the electric circuitry is turned off, which
PAGE 20 OF 48 | OWNER’S MANUAL 1185184 |