INSTALLATION | STRATOSTEAM COUNTERTOP STEAMER |
Figure 7 |
|
Water Drain |
|
| Stand |
| Pipe |
| 90° |
Air Gap |
|
Air Gap | Air Gap |
| Floor Drains |
STEP 4: WATER CONNECTION |
|
WARNING
Do not connect steamer to a hot water line. A hot water connection will damage the steamer.
NOTICE
To meet warranty requirements, the supply water must meet the following specifications:
Pressure | 30 to 60 PSI (205 to 410 kPa) |
Total Dissolved Solids (TDS) | 60 PPM or less |
Hardness | 2 grains (35 PPM) or less |
pH | 7.0 to 7.5 |
Connect a cold water line to the water inlet strainer on the back of the steamer, as shown in Figure 6. The connector on the steamer is a 1/4" (6 mm) compression fitting.
NOTE: To facilitate cleaning, and allow access to rear of the steamer, flexible connections are recommended. A shut off valve at (or near) the rear of the steamer is highly recommended. Also, an accessible water filter is recommended to help keep water quality within the requirements described above. See Figure 8 below.
Figure 8 |
|
Water Connection |
|
Cold |
|
Water | Steamer |
Supply |
|
Shut Off | Filter |
Valve |
|
PAGE 16 OF 48 | OWNER’S MANUAL 1185184 |