Southbend HDG-60-RE, HDG-60-M, HDG-72-RE, HDG-36-RE, G-72-M, HDG-48-M, HDG-36-M Installation, Unpack

Page 9

HEAVY DUTY COUNTERLINE

INSTALLATION

INSTALLATION

NOTICE

Installation must comply with National Fuel Gas Code, ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Installation Code, CAN/CGA-B149.2, as applicable.

These installation procedures must be followed by qualified personnel or warranty will be void.

Local codes regarding installation vary greatly from one area to another. The National Fire Protection Association, Inc. states in its NFPA 96 latest edition that local codes are the “authority having jurisdiction” when it comes to installation requirements for equipment. Therefore, installations should comply with all local codes.

Step 1: Unpack

IMMEDIATELY INSPECT FOR SHIPPING DAMAGE

All containers should be examined for damage before and during unloading. The freight carrier has assumed responsibility for its safe transit and delivery. If damaged equipment is received, either apparent or concealed, a claim must be made with the delivering carrier.

Apparent damage or loss must be noted on the freight bill at the time of delivery. The freight bill must then be signed by the carrier representative (Driver). If the bill is not signed, the carrier may refuse the claim. The carrier can supply the necessary forms.

A request for inspection must be made to the carrier within 15 days if there is concealed damage or loss that is not apparent until after the equipment is uncrated. The carrier should arrange an inspection. Be certain to hold all contents plus all packing material.

1.Uncrate carefully. Report any hidden damage to the freight carrier IMMEDIATELY.

2.Do not remove any tags or labels until unit is installed and working properly.

Step 2: Attach Countertop Legs, Mount on Counter, or Mount on Stand

The appliance can be mounted in several ways:

To mount it on short, countertop legs, go to Step 2a on page 10. To mount it directly on a countertop, go to Step 2b on page 11.

To mount it on an insulated base on a countertop, go to Step 2c on page 12.

To mount it on a stand that rests on the floor, go either to Step 2d on page 13 (for 24", 36", and 48" models) or to Step 2e on page 15 (for 60" and 72" griddle models).

INSTALLATION

OWNERS MANUAL 1182845 REV 8

PAGE 9

Image 9
Contents Heavy Duty Counterline Safety Precautions Table of Contents GAS Supply SpecificationsVentilation ClearancesModel Width Number and Size of Burners Total BTU Dimensions of Griddle ModelsConstruction of Griddle Models Dimensions of Charbroiler ModelsDimensions of Open TOP Models Construction of Charbroiler ModelsConstruction of Open TOP Models Installation UnpackAttach Countertop Legs, Mount on Counter, or Mount on Stand Installation on Countertop Legs Installation Installation on Insulated Base Installation on Floor Stand 24, 36, and 48 Models Owner ’S Manual 1182845 REV Installation on Floor Stand 60 and 72 Models Installation Attach Restraint for Appliances Mounted on Casters Connect Gas Supply Check Pilot and Burner Operation Final Positioning, Clearance Check, and Ventilation CheckFinal Installation Steps for Lava-Rock Charbroilers Final Installation Steps for Griddle ModelsLighting After GAS has Been Shut OFF OperationOperation of Thermostatic Griddle Models Operation of Manual Griddle Models Operation of Charbroiler Models Operation of OPEN-TOP Burner Models Daily CleaningOwner ’S Manual 1182845 REV Adjustment of Manifold GAS Pressure AdjustmentsAdjustment of Pilot Flame Charbroiler and OPEN-TOP Models Adjustment of Pilot Flame Griddle ModelsConversion from ONE Type of GAS to Another Adjustment of Burner FlameAdjustment of Griddle Thermostats Problem Look for TroubleshootingParts Index of Parts DiagramsGriddle Chassis Parts See parts list on previous page. Model HDG-24 is shown Thermostatic Griddle Gas System Parts Parts Manual Griddle Gas System Parts See parts list on previous page. Model HDG-36-M is shown Charbroiler Parts Parts Open Top Parts Parts Floor Stand Parts for 24, 36, and 48 Width Units See parts list on previous page. Model HDG-36 is shown Floor Stand Parts for 60 Width Units 1312 Countertop Legs and Insulated-Base Parts Heavy Duty Counterline Heavy Duty Counterline Heavy Duty Counterline Heavy Duty Counterline