Southbend HDG-48-M, HDG-60-M, HDG-72-RE, HDG-36-RE, G-72-M, HDG-36-M Specifications, GAS Supply

Page 4

SPECIFICATIONS

SPECIFICATIONS

HEAVY DUTY COUNTERLINE

SPECIFICATIONS

NOTICE

Installation must comply with National Fuel Gas Code, ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Installation Code, CAN/CGA-B149.2, as applicable.

Local codes regarding installation vary greatly from one area to another. The National Fire Protection Association, Inc. states in its NFPA 96 latest edition that local codes are the “authority having jurisdiction” when it comes to installation requirements for equipment. Therefore, installations should comply with all local codes.

Southbend reserves the right to change specifications and product design without notice. Such revisions do not entitle the buyer to corresponding changes, additions, or replacements for previously purchased equipment.

This product is intended for commercial use only, not for household use.

GAS SUPPLY

The serial plate is located on the interior side of the valve panel (see Figure 1 on page 3). It indicates the type of gas the unit is equipped to burn. All Southbend equipment is adjusted at the factory. Check type of gas on serial plate.

These models are design-certified for operation on natural or propane gases. The unit is shipped configured for the type of gas specified by the purchaser. A kit for conversion to a different type of gas may be purchased from Southbend (see page 30 for conversion instructions).

This appliance should be connected ONLY to the type of gas for which it is configured.

An adequate gas supply is imperative. Undersized or low pressure lines will restrict the volume of gas required for satisfactory performance. Fluctuations of more than 25% on natural gas or 10% on propane gas will create problems and affect burner operating characteristics. A 1/8" pressure tap is located on the manifold to measure the manifold pressure.

An adequate gas supply line to the unit should be no smaller than the inside diameter of the pipe from the unit to which it is connected.

Purge the supply line to clean out dust, dirt, or other foreign matter before connecting the line to the unit.

All pipe joints and connections must be tested thoroughly for gas leaks. Use only soapy water for testing on all gases. NEVER use an open flame to check for gas leaks. All connections must be checked for leaks after the unit has been put into operation. Test pressure should not exceed 14" W.C.

!CAUTION

THIS APPLIANCE AND ITS INDIVIDUAL SHUTOFF VALVE MUST BE DISCONNECTED FROM THE GAS SUPPLY PIPING SYSTEM DURING ANY PRESSURE TESTING OF THAT SYSTEM AT TEST PRESSURES IN EXCESS OF 1/2 PSIG (3.45 kPa).

THIS APPLIANCE MUST BE ISOLATED FROM THE GAS SUPPLY PIPING SYSTEM BY CLOSING ITS INDIVIDUAL MANUAL SHUTOFF VALVE DURING ANY PRESSURE TESTING OF THE GAS SUPPLY PIPING SYSTEM AT TEST PRESSURES EQUAL TO OR LESS THAN 1/2 PSIG (3.45 kPa).

PAGE 4

OWNERS MANUAL 1182845 REV 8

Image 4
Contents Heavy Duty Counterline Safety Precautions Table of Contents Specifications GAS SupplyClearances VentilationDimensions of Griddle Models Model Width Number and Size of Burners Total BTUDimensions of Charbroiler Models Construction of Griddle ModelsConstruction of Charbroiler Models Dimensions of Open TOP ModelsConstruction of Open TOP Models Unpack InstallationAttach Countertop Legs, Mount on Counter, or Mount on Stand Installation on Countertop Legs Installation Installation on Insulated Base Installation on Floor Stand 24, 36, and 48 Models Owner ’S Manual 1182845 REV Installation on Floor Stand 60 and 72 Models Installation Attach Restraint for Appliances Mounted on Casters Connect Gas Supply Final Positioning, Clearance Check, and Ventilation Check Check Pilot and Burner OperationFinal Installation Steps for Griddle Models Final Installation Steps for Lava-Rock CharbroilersOperation Lighting After GAS has Been Shut OFFOperation of Thermostatic Griddle Models Operation of Manual Griddle Models Operation of Charbroiler Models Operation of OPEN-TOP Burner Models Cleaning DailyOwner ’S Manual 1182845 REV Adjustments Adjustment of Manifold GAS PressureAdjustment of Pilot Flame Griddle Models Adjustment of Pilot Flame Charbroiler and OPEN-TOP ModelsAdjustment of Burner Flame Conversion from ONE Type of GAS to AnotherAdjustment of Griddle Thermostats Troubleshooting Problem Look forIndex of Parts Diagrams PartsGriddle Chassis Parts See parts list on previous page. Model HDG-24 is shown Thermostatic Griddle Gas System Parts Parts Manual Griddle Gas System Parts See parts list on previous page. Model HDG-36-M is shown Charbroiler Parts Parts Open Top Parts Parts Floor Stand Parts for 24, 36, and 48 Width Units See parts list on previous page. Model HDG-36 is shown Floor Stand Parts for 60 Width Units 1312 Countertop Legs and Insulated-Base Parts Heavy Duty Counterline Heavy Duty Counterline Heavy Duty Counterline Heavy Duty Counterline