Homelite HGCA5700 General Maintenance, Checking/CLEANING AIR Filter, Spark plug maintenance

Page 18

maintenance

WARNING:

When servicing, use only identical Homelite replacement parts. Use of any other parts may create a hazard or cause product damage.

WARNING:

Always wear eye protection with side shields marked to comply with ANSI Z87.1. Failure to do so could result in objects being thrown into your eyes, resulting in possible serious injury.

Only the parts shown on the parts list are intended to be repaired or replaced by the customer. All other parts should be replaced at an authorized service center.

GENERAL MAINTENANCE

Before each use, inspect the entire product for damaged, missing, or loose parts such as screws, nuts, bolts, caps, etc. Tighten securely all fasteners and caps and do not operate this product until all missing or damaged parts are replaced. Please call 1-800-242-4672 or contact an authorized service center for assistance.

Keep the generator in a clean and dry environment where it is not exposed to dust, dirt, moisture, or corrosive vapors. Do not allow the cooling air slots in the generator to become clogged with foreign material such as leaves, etc.

Do not use a garden hose to clean the generator. Water en- tering the fuel system or other internal parts of the unit can cause problems that will decrease the life of the generator.

To clean the unit:

Use a soft bristle brush and/or vacuum cleaner to loosen and remove dirt and debris.

Clean air vents with low pressure air that does not exceed 25 psi.

Wipe the exterior surfaces of the generator with a damp cloth.

checking/CLEANING AIR FILTER

See Figure 12.

For proper performance and long life, keep air filter clean.

Loosen the screws on the top and bottom of the air filter cover. Remove cover and set aside.

Remove the filter element.

If the filter element is dirty, clean with warm, soapy water. Rinse and let dry.

Apply a light coat of engine lubricant to the element, then squeeze it out.

Replace the element in the air filter unit.

Replace the air filter cover and tighten screws to

secure­ .

NOTE:  Do not run the generator without the air filter. Rapid engine wear will result.

changing engine lubricant

See Figure 13.

Remove the oil cap/dipstick.

Place a container underneath the oil drainage bolt to collect used lubricant as it drains.

Unscrew the oil drainage bolt and remove.

Allow lubricant to drain completely.

Reinstall the oil drainage bolt and tighten securely.

Refill with lubricant following the instructions in the

Checking/Adding­Lubricant section.

Reinstall the oil cap/dipstick.

Note:  Used lubricant should be disposed of at an ap- proved disposal site. See your local oil retailer for more information.

spark plug maintenance

See Figure 14.

The spark plug must be properly gapped and free of deposits in order to ensure proper engine operation. To check:

Remove the spark plug cap.

Clean any dirt from around base of spark plug.

Remove spark plug using wrench (not included).

Inspect spark plug for damage, and clean with a wire brush before reinstalling. If insulator is cracked or chipped, spark plug should be replaced.

NOTE:  If replacing, use the following recommended spark plug or equivalent:  NGK BPR4ES.

Measure plug gap. The correct gap is 0.028−0.031 in.

(0.7-0.8 mm). To widen gap, if necessary, carefully bend the ground (top) electrode. To lessen gap, gently tap ground electrode on a hard surface.

Seat spark plug in position; thread in by hand to prevent cross-threading.

Tighten with wrench to compress washer. If spark plug is new, use 1/2 turn to compress washer appropriate amount. If reusing old spark plug, use 1/8 to 1/4 turn for proper washer compression.

NOTE:  An improperly tightened spark plug will become very hot and could damage the engine.

Page 14 — English

Image 18
Contents Save this Manual for Future Reference Watt GeneratorHGCA5700 Series Neutral Bonded to FramePage Iii Off Apagado On EncendidoOff Table of Contents IntroductionImportant safety instructions 3 EnglishSpecific Safety Rules 4 EnglishSymbol Signal Meaning SymbolsSymbol Name DESIGNATION/EXPLANATION 5 EnglishSafety Labels Name DESIGNATION/EXPLANATION6 English Grounding warning­ Fuel warningEngine Lubricant warning Hot Surface warningExtension cord cable size #12 Wire #14 Wire #16 WireElectrical Electric motor loadsExample Power ManagementGenerator Capacity 9 EnglishFeatures Product SpecificationsKnow Your Generator Assembly UnpackingSecuring the handle Installing the wheelsOperation See Figures 6Applications Oxygenated FuelsChecking/CLEANING AIR Filter MaintenanceGeneral Maintenance Spark plug maintenanceDraining fuel tank/carburetor Cleaning the Exhaust Port and MufflerSpark arrestor Replacing Fuel FilterStorage time Prior to storing Maintenance ScheduleStorage 16 EnglishTroubleshooting Problem Possible Cause Solution17 English HOW to Obtain Warranty Service WarrantyWarranty Coverage Save Your Sales SlipPage Mise À LA Terre DU Générateur Table DES MatièresIntroduction 2 FrançaisAvertissement Conserver CES Instructions3 Français Règles de sécurité particulières 4 FrançaisSymbole Signal Signification SymbolesSymbole NOM Désignation / Explication 5 FrançaisAutocollants DE Sécurité NOM Désignation / Explication6 Français 7 Français Avertissement Concernant Le lubrifiant Moteur240 Caractéristiques électriques8 Français CalibreGestion DE L’ÉNERGIE 9 FrançaisCaractéristiques Déballage Installation DE Support DE CadreAssemblage Fixer LES Roues SUR LE Support DE CadreFixer LA Poignée Installation DES RouesUtilisation 12 FrançaisUtilisation DE Stabilisateur DE Carburant Avant D’UTILISER L’UNITÉVÉRIFICATION/AJOUT DE Carburant Carburants OxygénésINSPECTION/NETTOYAGE DU Filtre À AIR EntretienEntretien Général Vidange DE Le lubrifiant MoteurPARE-ÉTINCELLES Remplacement DU Filtre À EssenceNettoyage DE L’ORIFICE D’ÉCHAPPEMENT ET DU Silencieux Vidange DU Réservoir DE CARBURANT/ CarburateurDurée DU Remisage Avant LE Remisage RemisageCalendrier D’ENTRETIEN 16 FrançaisProblème Cause Possible Solution Dépannage17 Français Conserver LES Factures GarantieCouverture DE LA Garantie Comment Bénéficier D’UN Entretien Sous GarantiePage Peligro Conexión a tierra del generador Índice DE ContenidoIntroducción Pág. posteriorAdvertencia Instrucciones de seguridad importantesPeligro Guarde Estas InstruccionesReglas DE Seguridad Específicas Página 4 EspañolPrecaución SímbolosPeligro Símbolo Nombre Denominación / ExplicaciónEtiquetas DE Seguridad Nombre Denominación / ExplicaciónPágina 6 Español Símbolos Página 7 EspañolPrecaución Aspectos eléctricosCargas de motores eléctricos Página 8 EspañolAdministración DE LA Potencia Página 9 EspañolFamiliarícese CON EL Generador CaracterísticasEspecificaciones DEL Producto Retén Para EL CordónArmado DesempaquetadoInstalación de las ruedas ArmadoFuncionamiento Ajuste del mangoAntes DE Accionar LA Unidad Combustibles OxigenadosRevisión y limpieza del filtro de aire MantenimientoMantenimiento General Cambio del lubricante del motorParachispas MantenimientoLimpieza DEL Orificio DE Escape Y DEL Silenciador Drenaje del tanque del combustible y del carburadorPágina 16 Español AlmacenamientoPrograma DE Mantenimiento Tiempo de Antes de guardarlo AlmacenamientoCorrección de problemas Problema Causa Posible SoluciónPágina 17 Español Guarde SU Comprobante DE Compra GarantíaCobertura DE LA Garantía Exclusiones Y LimitacionesPage OPERATOR’S Manual Manuel D’UTILISATIONManual DEL Operador