Bradford-White Corp BWCV manuals
Household Appliance > Water Heater
When we buy new device such as Bradford-White Corp BWCV we often through away most of the documentation but the warranty.
Very often issues with Bradford-White Corp BWCV begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Water Heater Bradford-White Corp BWCV is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Water Heater on our side using links below.
Bradford-White Corp BWCV Warranty
64 pages 3.42 Mb
Installation and Operation Instructions Document 1270 Copper Brute IIInstallation and Operation Instructions for Hydronic Boiler Model BWCH Water Heater Model BWCV Sizes 500-2000
44 pages 3.28 Mb
Installation and Operation Instructions for Copper Brute IIRADFORD HITE B W Water Heater Model BWCV2 TABLE OF CONTENTSSECTION 1. General Information SECTION 2. Venting and Combustion Air SECTION 3. Gas Supply and Piping SECTION 4. Water Connections Copper Brute II Water Heater SECTION 5. Electrical Connections SECTION 6. Operating Instructions SECTION 7. Maintenance SECTION 8. Trouble Shooting SECTION 9. Wiring Diagrams 3 SECTION 1. General Information1.1 Introduction 1.2 Model Identication 4 1.3 Warranty1.4 Dimensions 1.5 Locating the Appliance5 Page 4Copper Brute II Page 5Figure 1. Dimensional Data. *Add 55 lbs. (25kg) for pump- mounted units. 1.6 Locating Pump-Mounted Water Heater with Respect to Storage Tank(s) 1.7 Locating Appliance for Correct Horizontal Vent/Ducted Air Distance From Outside Wall 6 SECTION 2. Venting and Combustion Air12 SECTION 3. Gas Supply and Piping3.1 Gas Supply and Piping 13 SECTION 4. Water Connections Copper Brute II Water Heater4.1 Water System Piping Water Heater 4.2 Hot Water Supply Piping Water Heater 4.3 Water Flow Requirements Water Heater14 Page 14Copper Brute II Page 15Table 8. Water Flow Requirements Figure 4. Water Heater Piping One Heater, One Tank. 15 Page 14Copper Brute II Page 158.MINIMUM INLET WATER TEMPERATUREIS 120F. Figure 5. Water Heater Piping Multiple Heaters, One Tank.LOCATIONOF FACTORY-MOUNTED PUMP KEY: 16 Page 16Copper Brute II Page 177.MINIMUM INLET WATER TEMPERATUREIS 120F. Figure 6. Water Heater Piping One Heater, Multiple Tanks. 17 Page 16Copper Brute II Page 178.MINIMUM INLET WATER TEMPERATUREIS 120F. Figure 7. Water Heater Piping Multiple Heaters, Multiple Tanks. 4.4 Combined Water Heating (potable) and Space Heating Water Heater 4.5 Freeze Protection Water Heater 18 SECTION 5. Electrical Connections20 SECTION 6. Operating Instructions30 SECTION 7. Maintenance34 SECTION 8. Trouble Shooting8.1 Resolving Lockouts 8.2 Delayed Ignition Possible Causes 8.3 Short Cycling 8.4 High Gas Consumption 8.5 Troubleshooting the Temperature Control 36 8.6 Troubleshooting Copper Brute II Controls43 Page 42Copper Brute II Page 43 terminal designations are as indicated. Note: Positions of eld wiring terminals may vary, but Figure 24. Field Wiring for Modes 1 - 5.TSTAT TERMINALSTRIP MODE1 MODE2 MODE3 MODE4 MODE5 44 B W Figure 25. Field Wiring for Mode 6. WARNING
Also you can find more Bradford-White Corp manuals or manuals for other Household Appliance.