Installation and Setup (Continued)
PNEUMATICCONNECTION
Important: Use care when working with compressed air.
The case sealer requires a 5.2 bar gauge pressure 110 liter/min [75 PSIG], @ 21°C, 1.01 bar [3.75 SCFM] compressed air supply. As shown in Figure
Note: A precision regulator is used to balance the top drive assembly. Due to the self- relieving feature of this regulator, a small amount of air continually vents to the atmo- sphere. This is normal and amounts to approximately 3 liter/min. [0.1 SCFM].
1.Read and remove safety tag from pneumatic "On/Off"valve.
2.Connect the main air supply line to the inlet side of the On/Off valve using the barbed fitting and hose clamp provided. The customer supplied air hose
(8 mm [5/16 inches] Inner Diameter) must be clamped tightly to the barbed fitting.
If another type of connector is desired, the barbed fitting can be removed and replaced with the desired
Always turn the air valve Off when the air supply line is being connected or disconnected.
3.Turn the air supply on by turning the air On/Off valve to On.
Note – The air valve has provisions for lock out/tag out according to plant regulations.
WARNING
•To reduce the risk associated with impact hazards:
−Always use appropriate supporting means when working under the upper drive assembly
4.Raise the upper drive assembly to full Up position by turning the drive assembly raising switch clockwise.
14