Troubleshooting Guide

The Troubleshooting Guide lists some possible machine problems, causes, and corrections. Also see Section II "Troubleshooting" for taping head problems.

Problem

Cause

Correction

 

 

 

 

Narrow boxes

Check machine specifications.

 

 

Boxes are narrower than

 

 

recommended, causing

 

 

slippage and premature belt

 

 

wear.

 

Worn drive belts or friction rings

Replace drive belts or friction

 

 

rings

Drive belts do not

Top taping head does not apply

Adjust the box height adjustment

convey boxes

enough pressure.

using the crank handle

 

Top flap compression rollers too

Readjust compression rollers

 

tight

 

 

Taping head applying spring holder

Replace spring holder

 

missing

 

 

Taping head applying spring set too

Reduce spring pressure

 

high

 

 

Worn or missing friction rings

Replace friction rings

 

Drive belt tension too low

Adjust belt tension

 

Electrical disconnect

Check power and electrical plug

Drive belts do not

Circuit breaker not at correct

Set to correct current value

turn

 

 

setting

 

 

Motor not turning

Evaluate problem and correct

 

Circuit breaker

 

 

Motor capacitor

 

 

Motor fan cover dented

 

 

 

 

Upper and lower

Machine's minimum height stop

Check manual to make sure

taping head

does not match tape head leg

taping heads match machine

mechanisms

length setting

setting

interfere with each

 

 

other

 

 

 

 

 

 

Worn belt

Replace belt

Drive belts break

Improper setup causing boxes to

 

 

jam

 

Light boxes tip

Upper upper head assembly down

Carefully adjust upper upper

back on exit

too far

head assembly

Squeaking noise

Dry compression rollers

Lubricate compression rollers

 

Lubricate column bearings

as boxes pass

Dry column bearings

through machine

Defective column bearings

Replace column bearings

 

 

 

 

 

Tape drum not centered

Reposition tape drum

Tape not centered

Centering guides not centered

Adjust centering guides

on box seam

 

 

 

Box flaps of unequal length

Check box specifications

 

 

 

(Continued)

30

Page 38
Image 38
3M 10700, MN55144-1000 manual Troubleshooting Guide, Problem Cause Correction