Operation (Continued)

Figure 3-2—Controls, Valves and Switches

Electrical On/Off Switch (Figure 3-2)

The box drive belts are turned on and off with the electrical switch on the side of the machine frame.

The case sealer has a circuit breaker located in the electrical enclosure on the left side of the machine frame. If circuit becomes overloaded and circuit breaker trips, unplug the machine electrical cord and determine cause of overload. After two minutes, plug machine electrical cord into outlet and restart machine by rotating the On/Off switch to Off (O) then On (I).

Main Air On/Off Valve/Pressure Regulator/

Filter (Figure 3-3)

This set of pneumatic components controls, regulates and filters plant air supply to the two separate control circuits of the case sealer.

On/Off Valve (Figure 3-2)

On—turn arrows on switch toward the front of the machine; Off—turn arrows on switch toward the left side of the machine.

Note: Turning air supply off automatically bleeds air pressure from the case sealer air circuits.

Always turn off the air when machine is not in use, when servicing the machine, or when connecting or disconnecting air supply line.

Note: The air valve has provisions for lockout/ tagout according to plant regulations.

Figure 3-3—On/Off Valve/Regulator/Filter

17

Page 25
Image 25
3M MN55144-1000, 10700 manual Main Air On/Off Valve/Pressure Regulator, On/Off Valve Figure