3.20Turning Your System On

System Configuration

3M Library Security System

 

 

 

3.20Turning Your System On

The power On/Off switch is a key switch located on one end of the corridor at the base of the electronics chassis. The 3Mt Detection System Model 3801/3802 is designed to be left on continuously.

To turn the system on, insert the key and turn the key switch to the ON position. The green light above the key switch will light, indicating the system is on.

They key should always be removed from the system to prevent tampering.

Allow two minutes for the system to warm up. A “DIAG9” will appear in the “Patron Counter/Diagnostic Display” during warm-up. Thereafter, the patron count or alarm count will be displayed.

3.21How to Verify System Operation

Your 3M detection system Model 3801/3802 should be inspected daily for proper operation.

System operation may be verified with the built-in Diagnostic Display located on one security panel. During normal operation, the current patron count or alarm count will be alterately displayed at 15 second intervals. A leading “P” indicates a patron count (for example, P123456). A leading “A” indicates an alarm count (for example, A123456).

If a system problem should occur, a code number will appear in the Diagnostic Display. Refer to the Troubleshooting Guide, Section 6, if a code number is present.

An alarm condition is indicated by an audible signal. The specific corridor in which an alarm condition exists is indicated by the light built into the top of panel A or C.

There is no need for repetitive walk-through testing.

3-16

E 3M 1999 September

Page 24
Image 24
3M 3802 3.20Turning Your System On, 3.21How to Verify System Operation, System Configuration, 3M Library Security System