Chapter 1 Siemens 9751 9006i DTMF Integration

Programming the Phone System

Table 1-2 ADDSCSU Parameter Settings for Answering Ports

Parameter

Required Setting

 

 

NYTPE

NAT

 

 

ACTCDE

(leave field blank)

 

 

HTLNIDX

(leave field blank)

 

 

DEVFUNC

EXTVCML

 

 

INS

Y

 

 

LCRCOSV1

0

 

 

LCRCOSV2

0

 

 

Step 3 Repeat Step 2 for each remaining SLMA voice messaging port that answers calls.

Step 4 Use the ADDSCSU command to create the first SLMA voice messaging port the sets MWIs. Each voice messaging port that sets MWIs must have the following parameters while the remaining parameters keep their default values.

Table 1-3 ADDSCSU Parameter Settings for MWI Ports

 

 

 

Parameter

Required Setting

 

 

 

 

 

 

 

 

STNO

<the extension number>

 

 

 

 

 

 

 

 

PEN

<the port equipment number>

 

 

 

 

 

 

 

 

 

DPLN

0

 

 

 

 

 

 

 

 

 

ITR

1 (assign the port to an ITR group that can dial subscribers,

 

 

 

 

but can’t be dialed by subscribers)

 

 

 

 

 

 

 

 

COS1

<a class of service with only MSCWCAP (message-waiting

 

 

 

 

capability)>

 

 

 

 

 

 

 

 

COS2

<a class of service with only MSCWCAP (message waiting

 

 

 

 

capability)>

 

 

 

 

 

 

 

 

COSX

(leave field blank)

 

 

 

 

 

 

 

 

PUBSCR

<the PSTN prefix plus the extension number>

 

 

 

 

 

 

 

 

NYTPE

NAT

 

 

 

 

 

 

 

 

ACTCDE

(leave field blank)

 

 

 

 

 

 

 

 

Siemens 9751 9006i DTMF Integration Guide

 

 

1-6

 

 

 

OL-1747-02

 

 

 

 

 

Page 18
Image 18
Able Planet OL-1747-02 manual Nytpe NAT Actcde