Able Planet OL-1747-02 manual Type VCE

Models: OL-1747-02

1 50
Download 50 pages 25.85 Kb
Page 20
Image 20

Chapter 1 Siemens 9751 9006i DTMF Integration

Programming the Phone System

Table 1-4 ADDHUNT Parameter Settings

Parameter

Required Setting

 

 

TYPE

VCE

 

 

AC

<the pilot number of the hunt group>

 

 

DPLN

0

 

 

STNP

<the extension numbers of the answering voice messaging

 

ports>

 

 

NAME

CISCO UNITY VOICE MESSAGING

 

 

CQMAX

10 (the number of subscribers that may be queued when all

 

the ports are busy)

 

 

FNA

N

 

 

STYPE

CIR (circular hunt group)

 

 

Make sure that the phone system sends calls only to Cisco Unity voice ports that are set to Answer Calls on the System > Ports page in the Cisco Unity Administrator. Calls sent to a voice messaging port not set to Answer Calls cannot be answered by Cisco Unity and may cause other problems.

Step 7 Go to menu 1.1 - System Parameters and set the following parameters.

Table 1-5 Menu 1.1 - System Parameter Settings

Parameter

Required Setting

 

 

 

Type of PBX VPMOD is on

2

- Other

 

 

Number of digits in an

(leave field blank)

extension (Used for MWI)

 

 

 

 

 

Sender ID used for Telephone

2

- Calling Party if Known

Answering Messages

 

 

 

 

 

ACP Used for Integration

N

 

 

 

 

 

Siemens 9751 9006i DTMF Integration Guide

1-8

OL-1747-02

Page 20