<min rate> This entry specifies the lowest data transfer rate which the modem may establish a connection.

<max rate> This parameter specifies the highest speed at which the modem may establish a connection.

S0

Number of Rings to Auto-answer

The modem automatically goes off-hook and initiates a data mode-answer mode handshake after detecting the specified number of rings. A value of zero ( 0 ) disables auto-answer mode. Entering a value from 1 to 255 enables auto-answer mode.

Range: 0-255 rings

Default: 0

S2

Escape Character

The value of S2 specifies an ASCII value for the character used to enter command mode. A value over 127 disables the escape sequence.

Range: 0-127

Default: 43

S3

Carriage Return Character

S3 specifies the AT command string terminator and modem response code termi- nator. The default is <CR> or carriage return (ASCII 13).

Range: 0-127

Default: 13

S4

Line Feed Character

The value of S2 specifies the line feed character.

Range: 0-127

Default: 10

S5

Backspace Character

S5 specifies the backspace character that is used to delete the last entered charac- ter. The default value is <backspace> (ASCII 8).

28