4-32
Adaptec SCSI RAID 2120S/2200S Software User’s Guide
Diagnostic Commands
Use the diagnostic commands to provide technical support
personnel with information needed to troubleshoot controller
problems. Use these commands only under the direction of
technical support personnel.
Command Summary:
diagnostic clear boot_parameters
Clears all boot-time parameters.
diagnostic dump structures{string}
Saves internal data structures.
Parameters
{string}—Name of the file to contain the internal data
structures.
diagnostic dump text
Displays diagnostic information.
diagnostic load_containers
When in maintenance mode, allows arrays to be loaded so
they can be verified.
diagnostic moderation set count
Sets the default interrupt count on the controller.
diagnostic moderation set timer {integer}
Sets the default interrupt timer on the controller.
Parameters
{integer}—Value to set as the default interrupt timer.
diagnostic moderation show count
Displays the default interrupt count on the controller.
diagnostic moderation show timer
Displays the default interrupt timer on the controller.
UG.book Page 32 Saturday, October 26, 2002 12:08 PM