2-13
Using Adaptec RAID Configuration
The Ctrl-B option in ACU moves any array to be array 00.
Using this option repeatedly allows any boot order to be
chosen.
The default is Disabled.
Physical Drives Display during POST— The default is
Disabled.
CD-ROM Boot Support — The default is Enabled.
Removable Media Devices Support — The default is
Enabled.
Alarm Control — The default is Enabled.
You cannot set the following options:
NVRAM State — Displays the current status of the NVRAM
cache. This option is available only for controllers that have
a battery and is for display only. In normal operation it will
display Clean.
Controller Memory Size — Displays the amount of memory
installed on the controller.
Using the SCSI Configuration Utility
The SCSI Configuration Utility enables you to modify the SCSI
Channel Interface Definitions and SCSI Device Configuration
Options.
To access the SCSI Configuration Utility:
1When you turn on or reboot your system, press Ctrl+A to access
the Adaptec RAID Configuration (ARC) utilities when
prompted by the following message:
Press <Ctrl><A> for Adaptec RAID Configuration Utility
2If multiple controllers are installed, select the controller you
want to configure and press Enter.
3From the ARC menu, select SCSISelect Utility.
The Controller Configuration and SCSI Configuration menu
options are displayed.
4Select SCSI Configuration.
UG.book Page 13 Saturday, October 26, 2002 12:08 PM