Adaptec SCSI RAID 2120S/2200S Software User’s Guide
enclosure set interval {second}
Sets the monitor reporting interval (in seconds).
Parameters
{second}—Number of seconds for the monitor reporting interval.
enclosure set power {enclosure} {powersupply}
Turns on or off a specific power supply.
Parameters
{enclosure}—ID associated with the enclosure management device.
{powersupply}—Unit number associated with the power supply.
Switches
/off—Specifies whether to turn on or off the power supply associated with the unit number.
enclosure set scsiid {enclosure} {slot} {device_id}
Sets the SCSI ID of the device slot.
Parameters
{enclosure}—ID associated with the enclosure management device.
{slot}—Unit number associated with the device slot to assign a SCSI channel number.
{device_id}—ID of the SCSI device.
enclosure set temperature {enclosure} {degree}
Sets the temperature threshold.
Parameters
{enclosure}—ID associated with the enclosure management device on which to set a temperature threshold.
{degree}—Temperature (in degrees Fahrenheit from 0 to 255).