2. Acyclic parameter table Thyro-C07

Table B: Thyro-C07 controller parameters slot 1-8

Controller parameter

Index

 

Symbol

 

Name

 

Data

 

Value

Combo-opt.

 

 

 

 

 

type

 

range

 

 

 

 

 

 

 

 

 

1

 

I_TYP

 

Controller type current

 

u16

 

0…

 

 

 

 

 

 

2

 

U_TYP

 

Controller supply voltage

 

u16

 

0…1000

 

3

 

P_TYP

 

Controller type output power

 

u32

 

0…

 

6

 

BETR

 

Operating mode

 

u16

 

0…3

reserved, TAKT, VAR, QTM

7

 

AN1

 

Phase angle of 1st half wave

 

u16

 

0…180

 

8

 

SST

 

 

 

u16

 

0…1000

 

9SDN

10T0

11MP

12TSMAX

13TSMIN

14V_IE

15H_IE

16RE

17TI_1

18KP_1

19KR_1

21UEMA

22IEMA

23PMA

24SW_ENABLE

27SW_REGLER

28OF_1

29FA_1

30SPG_MIN

31SPG_MAX

32UN_S

33RELAIS_CTRL_2

34LASTBRUCH_MIN_ ABS

36SYNC_ADR

37IMAB

38STA_RE

39STE_RE

41MOSI_FA

42DAC_1_CTRL

44VERS_T

45VERS_M

46VERS_J

49RELAIS_CTRL

56MITTEL

84TEMP

109MITTEL_2

110OF_2

111FA_2

112DAC_2_CTRL

115MITTEL_3

116OF_3

117FA_3

118DAC_3_CTRL

119U_MIN

120U_MAX

121I_MIN

122I_MAX

123P_MIN

124P_MAX

Soft stop duration (given)

Cycle period duration

Minimum interval

Maximum cycle turn on time

Minimum cycle turn on time

Front pulse stop

Back pulse stop

Control (analog output value)

PI controller, I part

PI controller, P part

PI controller, counter P part

Temperature coefficient of the heating tape Effective voltage setpoint maximum Effective current setpoint maximum Power setpoint maximum

Setpoint activation Setpoint x2.4

Actual value output offset 1

Scale end value actual value output 1 Mains voltage monitoring min.

Mains voltage monitoring max. Undercurrent monitoring Relay configuration 2

Load fault, minimum value

Synchro cycle address

Pulse switch-off in case of failure Control start controller analog setpoint Control end controller analog setpoint Peak current value limit

Analog output configuration 1 Version day

Version month Version year Controller inhibit Relay configuration 1 Save

Averaging analog output 1 Temperature Averaging analog output 2 Actual value output offset 2

Scale end value actual value output 2 Analog output configuration 2 Averaging analog output 3

Actual value output offset 3

Scale end value actual value output 3 Analog output configuration 3 Voltage limit minimum

Voltage limit maximum Current limit minimum Current limit maximum Power limit minimum Power limit maximum

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u32

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u16

u32

u32

0…1000

0…1000

0…10

1…T0

0…T0

0…180

0…180

0…9

0= aus 0…65535 0= aus 0…65535 0…65535 0…65535 0… 0… 0… 0…3 0…4096 0…4096 0…4096 0…1000 0…1000 0…1 0…65535 0…4505

0…65535

0…65535

0…65535

0…65535

0…4096

0…11

1…31

1…12

0…9999

0…1

0…65535

0…1

0…65535 -50…150 0…65535 0…4096 0…4096 0…11 0…65535 0…4096 0…4096 0…11 0…65535 0…65535 0…65535 0…65535 0… 0…

Uload2, Uload eff, Iload2, Iload eff, reserved, real power, reserved, reserved, without regulation, temperature

bit0=1 setpoint x2.4 active, bit1=1 setpoint master active

off, on bit coded

bit coded

off, on bit coded off, save