Chapter 5 299
Language Reference
[:SENSe]:SWEep Subsection
Factory Preset
and *RST: Linear
Remarks: Refer to the Users Guide for detailed information on the
interactions of this command with other functions.
History: Added with firmware revision A.08.00.
Front Panel
Access: FREQU ENCY, Scale Type
Sweep Time
[:SENSe]:SWEep:TIME <time>
[:SENSe]:SWEep:TIME?
Specifies the time in which the instrument sweeps the d isplay.
Factory Preset
and *RST: 120.8m s
Range: The range depends upon the installed options, number of sweep
points, and firmware revision of your instrument. See Sweep
Time Range in the Specifications Guide for details.
Default Unit: seconds
Remarks: A span value of 0 Hz causes t he analyzer to enter zero span
mode. In zero span the X-axis r epresents time rather than
frequency. In this mode, the sweep time may be set to faster
values when Option AYX is installed.
Front Panel
Access: Sweep, Sweep Tim e Auto Man
Automatic Sweep Time
[:SENSe]:SWEep:TIME:AUTO OFF|ON|0|1
[:SENSe]:SWEep:TIME:AUTO?
Automatically selects the fastest sweep time for the current settings.
Factory Preset
and *RST: On
History: This command function changed with firmware revision
A.08.00. With:AUTO ON in zero span , an error will be
generated.
Front Panel
Access: Sweep, Sweep Tim e Auto Man