Language Reference

CALCulate:LLINe Subsection

Control Limit Line Testing

:CALCulate:LLINe[1]2:STATe OFFON01

:CALCulate:LLINe[1]2:STATe?

Turns limit line testing on/off. The limit and margin will only be tested if they are displayed. Use :CALCulate:LLINe[1]2:DISPlay to turn on the display of limit lines, and :CALCulate:LLINe[1]2:MARGin:STATe to turn on the display of margins. If margin and limit display are both turned off, limit test is automatically turned off. Use :CALCulate:LLINe[1]2:FAIL? to return the state of pass or fail after limit line state has been turned on.

Factory Preset

 

and *RST:

Off

Front Panel

 

Access:

Display, Limits, Limit 12, Limit On Off

Select the Type of Limit Line

:CALCulate:LLINe[1]2:TYPE UPPerLOWer

:CALCulate:LLINe[1]2:TYPE?

Sets a limit line to be either an upper or lower type limit line. An upper line will be used as the maximum allowable value when comparing with the data. A lower limit line defines the minimum value.

Factory Preset

 

and *RST:

Upper; not affected by preset

Remarks:

If a margin has already been set for this limit line, and this

 

command is used to change the limit type, then the margin value

 

is reset to 0 dB.

Front Panel

 

Access:

Display, Limits, Limit 12, Type Upper Lower

Chapter 5

215

Page 215
Image 215
Agilent Technologies Model  A.08.xx manual Control Limit Line Testing, Select the Type of Limit Line

Model A.08.xx specifications

Agilent Technologies has long been a leader in the field of measurement and analytical instrumentation, and their Model A.08.xx is a prime example of this expertise. This advanced instrument is designed for a wide array of applications, spanning from life sciences to chemical analysis, offering unparalleled precision and reliability to meet the demands of laboratory environments.

One of the main features of the A.08.xx model is its advanced measurement capabilities. The instrument boasts a high-resolution detector that provides exceptional sensitivity, allowing researchers to detect even trace levels of analytes in complex samples. The enhanced signal-to-noise ratio is particularly beneficial for users working with low concentrations, ensuring accurate results without the need for laborious sample preparation.

The A.08.xx is equipped with state-of-the-art technologies that significantly enhance its performance. One such technology is its multi-wavelength detection system, which allows simultaneous analysis of multiple compounds within a single run. This not only boosts efficiency but also reduces the time required for method development and validation. Additionally, the model utilizes sophisticated software for data analysis, providing users with intuitive tools to interpret results quickly and effectively.

Another characteristic of the A.08.xx is its robust build quality and user-friendly interface. Designed for rigorous laboratory use, the instrument can withstand the demanding conditions of a busy research environment. Its intuitive touchscreen display simplifies operations, allowing users to set up experiments and navigate through various functions with ease. This user-centric design reduces the learning curve for new operators, enhancing productivity in the lab.

The A.08.xx also incorporates connectivity features that align with modern laboratory needs. With options for remote monitoring and data sharing, researchers can easily collaborate and access results in real-time, streamlining workflows and promoting innovation.

In conclusion, Agilent Technologies’ Model A.08.xx is not just an analytical instrument; it is a comprehensive solution for researchers and scientists seeking reliability and performance in their analytical work. With its advanced measurement capabilities, cutting-edge technologies, and user-friendly design, it continues to set the standard for excellence in laboratory instrumentation, facilitating groundbreaking research across various scientific fields.