Agilent Technologies Model A.08.xx manual

Models: Model A.08.xx

1 349
Download 349 pages 21.69 Kb
Page 105
Image 105

Programming Examples

Using Marker Peak Search and Peak Excursion

#include <stdlib.h> #include <math.h> #include <conio.h> #include <ctype.h> #include <string.h> #include "visa.h"

#define hpESA_IDN_E4401B "Hewlett-Packard, E4401B" #define hpESA_IDN_E4411B "Hewlett-Packard, E4411B" #definehpEMC_IDN_E7401A "Hewlett-Packard, E7401A"

ViSession

defaultRM, viESA;

ViStatus

errStatus;

ViChar

 

cIdBuff[256]= {0};

char

cEnter = 0;

int

iResult = 0;

/*Set the input port to 50MHz amplitude reference*/ void Route50MHzSignal()

{

viQueryf(viESA, "*IDN?\n", "%t", &cIdBuff);

iResult = (strncmp( cIdBuff, hpESA_IDN_E4401B, strlen(hpESA_IDN_E4401B)) && strncmp( cIdBuff, hpESA_IDN_E4411B, strlen(hpESA_IDN_E4411B)) && strncmp( cIdBuff, hpEMC_IDN_E7401A, strlen(hpEMC_IDN_E7401A)));

if( iResult == 0 )

{

/*Set the input port to the 50MHz amplitude reference for the models*/ /*E4401B, E4411B and E7401A*/

viPrintf(viESA,"CAL:SOUR:STAT ON \n");

}

else

{

/* For the analyzers having frequency limits >= 3GHz, prompt the user*/ /* to connect the amplitude reference output to the input*/

printf ("Connect AMPTD REF OUT to the INPUT \n"); printf ("......Press Return to continue \n");

scanf( "%c",&cEnter);

/*Externally route the 50MHz Signal*/ viPrintf(viESA,"CAL:SOUR:STAT ON \n");

}

}

void main()

{

Chapter 3

105

Page 105
Image 105
Agilent Technologies Model  A.08.xx manual

Model A.08.xx specifications

Agilent Technologies has long been a leader in the field of measurement and analytical instrumentation, and their Model A.08.xx is a prime example of this expertise. This advanced instrument is designed for a wide array of applications, spanning from life sciences to chemical analysis, offering unparalleled precision and reliability to meet the demands of laboratory environments.

One of the main features of the A.08.xx model is its advanced measurement capabilities. The instrument boasts a high-resolution detector that provides exceptional sensitivity, allowing researchers to detect even trace levels of analytes in complex samples. The enhanced signal-to-noise ratio is particularly beneficial for users working with low concentrations, ensuring accurate results without the need for laborious sample preparation.

The A.08.xx is equipped with state-of-the-art technologies that significantly enhance its performance. One such technology is its multi-wavelength detection system, which allows simultaneous analysis of multiple compounds within a single run. This not only boosts efficiency but also reduces the time required for method development and validation. Additionally, the model utilizes sophisticated software for data analysis, providing users with intuitive tools to interpret results quickly and effectively.

Another characteristic of the A.08.xx is its robust build quality and user-friendly interface. Designed for rigorous laboratory use, the instrument can withstand the demanding conditions of a busy research environment. Its intuitive touchscreen display simplifies operations, allowing users to set up experiments and navigate through various functions with ease. This user-centric design reduces the learning curve for new operators, enhancing productivity in the lab.

The A.08.xx also incorporates connectivity features that align with modern laboratory needs. With options for remote monitoring and data sharing, researchers can easily collaborate and access results in real-time, streamlining workflows and promoting innovation.

In conclusion, Agilent Technologies’ Model A.08.xx is not just an analytical instrument; it is a comprehensive solution for researchers and scientists seeking reliability and performance in their analytical work. With its advanced measurement capabilities, cutting-edge technologies, and user-friendly design, it continues to set the standard for excellence in laboratory instrumentation, facilitating groundbreaking research across various scientific fields.