Language Reference

TRIGger Subsystem

Factory Preset

 

and *RST:

Positive

Front Panel

 

Access:

Trig, External Pos Neg

Trigger Offset

:TRIGger[:SEQuence]:OFFSet <64 bit floating point value>

:TRIGger[:SEQuence]:OFFSet?

This command sets the trigger offset.

Factory Preset

 

and *RST:

0 seconds

Example:

:TRIG:SEQ:OFFS 1.0s

Range:

Hardware specific; dependent upon the ADC being used,

 

current state, and the number of sweep points.

Default Unit:

seconds

Remarks:

Trigger offset refers to the specified time interval before or after

 

the trigger event from which data is to be written to the trace,

 

and then displayed. Ordinarily, the trigger offset value is zero,

 

and trace data is displayed beginning at the trigger event. A

 

negative trigger offset value results in the display of trace data

 

prior to the trigger event. A positive trigger offset value results

 

in an effective delay in the display of trace data after the trigger

 

event.

 

The trigger offset value used when the feature is enable will

 

depend on the following parameters:

 

• Normal trigger offset value originally entered

 

• Specific instrument hardware in use

 

• Sweep time

 

• Number of sweep points

 

The effective trigger offset value will be re-calculated whenever

 

any of these parameters change.

Front Panel

 

Access:

Trig, Trig Offset

Chapter 5

335

Page 335
Image 335
Agilent Technologies Model  A.08.xx manual Trigger Offset, Trigseqoffs 1.0s

Model A.08.xx specifications

Agilent Technologies has long been a leader in the field of measurement and analytical instrumentation, and their Model A.08.xx is a prime example of this expertise. This advanced instrument is designed for a wide array of applications, spanning from life sciences to chemical analysis, offering unparalleled precision and reliability to meet the demands of laboratory environments.

One of the main features of the A.08.xx model is its advanced measurement capabilities. The instrument boasts a high-resolution detector that provides exceptional sensitivity, allowing researchers to detect even trace levels of analytes in complex samples. The enhanced signal-to-noise ratio is particularly beneficial for users working with low concentrations, ensuring accurate results without the need for laborious sample preparation.

The A.08.xx is equipped with state-of-the-art technologies that significantly enhance its performance. One such technology is its multi-wavelength detection system, which allows simultaneous analysis of multiple compounds within a single run. This not only boosts efficiency but also reduces the time required for method development and validation. Additionally, the model utilizes sophisticated software for data analysis, providing users with intuitive tools to interpret results quickly and effectively.

Another characteristic of the A.08.xx is its robust build quality and user-friendly interface. Designed for rigorous laboratory use, the instrument can withstand the demanding conditions of a busy research environment. Its intuitive touchscreen display simplifies operations, allowing users to set up experiments and navigate through various functions with ease. This user-centric design reduces the learning curve for new operators, enhancing productivity in the lab.

The A.08.xx also incorporates connectivity features that align with modern laboratory needs. With options for remote monitoring and data sharing, researchers can easily collaborate and access results in real-time, streamlining workflows and promoting innovation.

In conclusion, Agilent Technologies’ Model A.08.xx is not just an analytical instrument; it is a comprehensive solution for researchers and scientists seeking reliability and performance in their analytical work. With its advanced measurement capabilities, cutting-edge technologies, and user-friendly design, it continues to set the standard for excellence in laboratory instrumentation, facilitating groundbreaking research across various scientific fields.