RESERVOIR

MAINTENANCE

MAINTENANCE

RESERVOIR

Mnt-FL-0080

The reservoir stores hydraulic system oil. The breather cap which is mounted on top of the reservoir prevents a pressure buildup or vacuum from occurring in the tank as oil level changes. Their is also an oil filler cap which is used to fill the reservoir with oil. To help prevent dirt from entering the tank, clean the top of the reservoir before removing the cap. THE BREATHER CAP HOLDS APPROX 11 PSI PRESSURE IN TANK.

REMOVE FILLER CAP SLOWLY

The oil level sight glass is located on the side of the reservoir. The oil level should be even with the sight glass and checked with the cutter unit in the transport position. The oil temperature should not exceed 180 degrees F.

The oil return hoses are connected to the hydraulic filter on top of the reservoir. Oil is returned from cutter unit cooling tubes and filtered before entering the hydraulic reservoir.

SOLENOID CONTROL VALVE

A. CONTROL VALVE B. SOLENOID

The solenoid control valve directs oil flow from the hydraulic pump. When the mower ON/OFF switch is in the "ON" position, the solenoid is energized and the spool within the valve is positioned to direct oil to the cuttershaft motor.

When the mower ON/OFF switch is in the "OFF" position, oil pressure within the valve pushes the spool back which allows the oil to circulate through the cutter unit before returning to the reservoir. When the flow of oil to the motor

VERSA PRO 03/09

Maintenance Section 5-14

© 2009 Alamo Group Inc.

Page 154
Image 154
Alamo 803350C manual Reservoir, Solenoid Control Valve, Maintenance, Mnt-FL-0080