Installation
BreezeMAX Wi² and BreezeACCESS Wi² System Manual 23
2Expose the RJ-45 connector under the sealing cap on the Ethernet cable and
connect to the SU-ODU RJ-45 connector (Figure 2-9).
3Put the sealing cap back in its place. Make sure that the small protrusion on
the side of the cap fits inside the hole on the connector's protective body.
4Connect the other end of the Ethernet cable to the SU port on the Wi² unit.
5Verify that the O-ring supplied with the service box kit is in place, attach the
service box to the unit and tighten the top nut.
6Use appropriate sealing material to protect the connection to the SU-ODU
against moisture and humidity. Use removable sealing material to enable
future access to the connector.
Figure 2-8: Sealing Cap
Figure 2-9: Connecting the SU-ODU connector and inserting the Sealing Cap
NOTE
Use high quality sealing material such as Scotch® 130C Linerless Rubber Splicing Tape from 3M to
ensure IP-67 compliant protection against dust and water.
groove