Wiring Length Guidelines
Refer to the following table for the wiring length information related to the target MAX unit:
MAX-CSE and MAX-CSD10 @ 500 mA
Wire size | Maximum wiring length |
|
|
18 AWG | 216.76 feet (66.07 meters) |
|
|
20 AWG | 137.61 feet (41.94 meters) |
|
|
22 AWG | 88.78 feet (27.06 meters) |
|
|
24 AWG | 54.15 feet (16.50 meters) |
|
|
Preparing Captive Wires
You will need a wire stripper and
Never
1.Strip 0.25 inch (6.35mm) of insulation off all wires.
2.Insert each wire into the appropriate opening on the connector (according to the wiring diagrams and connector types described in this section).
3.Tighten the screws to secure the wire in the connector. Do not tighten the screws excessively, as doing so may strip the threads and damage the connector.
Wiring a Power Connection
To use the
PWR +
GND -
To the rear of the MAX unit
FIG. 3
Power Supply
Wiring Guidelines - Indirect Power (via PoE)
Any
PoE connections work with all existing Category (CAT) 3, 4, 5, 5e or 6 network cabling (including patch cables and