Configuring Communication
Associating a MAX-CSD10 Unit to a Target Master
1.From the Decoder Manager, click the NetLinx link to open the Netlinx Master page.
2.In the Connection Mode
3.Enter the new Master IP/URL number.
For more detailed information on communicating with a target Master, refer to the procedures outlined within the Communicating with the Target Master via an IP section on page 55.
Changing the MAX’s Device Number
The
Changing the MAX-CSE Device Number via the UI
1.Refer to step 4 of the previous Associating the MAX Unit to a Target Master section on page 57 to locate the Device Number field.
2.Enter a new
3.After the new connection to the target NetLinx Master is established, the MAX unit is displayed within the current System’s Online Tree tab using the new device value (FIG. 35).
Changing the MAX-CSE Device Number via Studio
1.Establish a valid connection between the target Master and the source MAX unit. Refer to the previous section for more detailed information.
2.Access the Device Addressing dialog (FIG. 36) by either one of these two methods:
Select Diagnostics > Device Addressing from the Main menu.
Device Address
(original device value)
Enter new device value
FIG. 36 Device Addressing dialog (changing the device value)
3.Select the Change Device checkbox from the Device to Change section.
4.Verify the Current value and enter the New Device value for the source MAX device.
5.Click the Change Device/System Number button. This configures the specified MAX unit to accept the new value and incorporate the information (the system information in the Workspace window refreshes and then displays the new information).
6.Click Done to close the Device Addressing dialog.
7.Navigate back to the IP Settings page on the UI and click the Reboot button to cycle power to the unit and save the new information.
59 | |
|
|