Recommended NetLinx Device Numbers

Configuring Communication

8.On the target Master, click Reboot (from the Tools > Reboot the Master Controller dialog) and wait for the System Master to reboot. The STATUS and OUTPUT LEDs should begin to alternately blink

during the incorporation. Wait until the STATUS LED is the only LED to blink.

9.Press Done once until the Master Reboot Status field reads *Reboot of System Complete*.

10.Click the OnLine Tree tab in the Workspace window to view the devices on the System.

The default System value is one (1).

11.Right-click the associated System number (or anywhere within the tab itself) and select Refresh System. This establishes a new connection to the specified System and populates the list with devices on that system.

12.Use Ctrl+S to save your existing NetLinx Project with the new changes.

Recommended NetLinx Device Numbers

• 1 - 255

• Axcess Devices use Axcess standards

• 301 - 3072

• NetLinx CardFrames start at frame number 25 - (frame# * 12) + Card #

• 5001 - 5999

• ICSNet and IP NetLinx devices: NXI, NXM-COM2, NXM-IRS4, etc.

• 6001 - 6999

• ICSNet and IP Landmark devices: PLH-VS8, PLH-AS16, PLB-AS16

• 7001 - 7999

• InConcert Devices

• 8001 - 8999

• PCLink Device: PCLink devices are PC programs

10000 - 31999 • ICSNet Panels: DMS, IMS, and future panels

33001 - 36863 • Virtual devices: these start at 33001

32001 - 32767 • Dynamic devices: the actual range used by Master

32768 - 36863 • Virtual devices: the actual range used by Master

Using the ID Button to Change the MAX-CSE’s Device Value

1.Access the Device Addressing dialog (FIG. 37) by selecting Diagnostics > Device Addressing from NetLinx Studio’s main menu.

Enter the new Controller value

3.Press the on-screen Start Identify Mode button. Assign the new value to the MAX unit

AB

FIG. 37 Device Addressing dialog (using the ID mode to set the MAX device value)

The ID button on the front of the MAX unit can also be used to reset the unit back to its factory-default parameters. Press and hold the button for 10 seconds to reset the parameters and reboot the MAX unit.

2.Locate the Device field (A in FIG. 37) and enter the new value for the MAX unit. This value must fall within a range of 0 - 32767.

3.Press the on-screen Start Identify Mode button.