AMX Mio Modero R-4 manual Button Commands, Ani, Apf

Models: Mio Modero R-4

1 102
Download 102 pages 12.65 Kb
Page 55
Image 55

Programming the Mio R-4

"^" Button Commands

These Button Commands are used in the NetLinx protocol and are case insensitive.

All commands that begin with "^" have the capability of assigning a variable text address range and button state range. A device must first be defined in the NetLinx programming language with values for the Device: Port: System (in all programming examples - Remote is used in place of these values).

Variable text ranges allow you to target one or more variable text channels in a single command.

Button State ranges allow you to target one or more states of a variable text button with a single command.

The "." Character is used for the 'through' notation, also the "&" character is used for the 'And' notation.

"^" Button Commands

^ANI

Run a button animation (in 1/10 second).

Run a button

Syntax:

animation

"'^ANI-<vt addr range>,<start state>,<end state>,<time>'"

(in 1/10 second)

Variable:

 

 

• variable text address range = 1 - 4000.

 

• start state = Beginning of button state (0= current state).

 

• end state = End of button state.

 

• time = In 1/10 second intervals.

 

Example:

 

SEND_COMMAND Panel,"'^ANI-500,1,25,100'"

 

Runs a button animation at text range 500 from state 1 to state 25 for 10 second.

 

 

^APF

Add page flip action to a button if it does not already exist.

Add page flip

Syntax:

action to a button

"'^APF-<vt addr range>,<page flip action>,<page name>'"

if it does not

Variable:

already exist

• variable text address range = 1 - 4000.

 

 

• page flip action = Stan[dardPage] - Flip to standard page

 

Prev[iousPage] - Flip to previous page

 

Show[Popup] - Show Popup page

 

Hide[Popup] - Hide Popup page

 

Togg[lePopup] - Toggle popup state

 

ClearG[roup] - Clear popup page group from all pages

 

ClearP[age] - Clear all popup pages from a page with the

 

specified page name

 

ClearA[ll] - Clear all popup pages from all pages

 

• page name = 1 - 50 ASCII characters.

 

Example:

 

SEND COMMAND Device,"'^APF-400,Stan,Main Page'"

 

Assigns a button to a standard page flip with page name 'Main Page'.

 

 