Programming the Mio R-4

"^" Button Commands (Cont.)

^BWW

Set the button word wrap feature to those buttons with a defined address range. By

Set the button

default, word-wrap is Off.

Syntax:

 

word wrap

 

feature to those

"'^BWW-<vt addr range>,<button states range>,<word wrap>'"

buttons with a

Variable:

 

defined address

 

 

 

range.

• variable text address range = 1 - 4000.

 

• button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons

 

1 = Off state and 2 = On state).

 

• word wrap = (0=Off and 1=On). Default is Off.

 

Example:

 

 

SEND_COMMAND Device,"'^BWW-500,1,1'"

 

Sets the word wrap on for the button’s Off state.

 

 

^CPF

Clear all page flips from a button.

Clear all page flips

Syntax:

 

from a button

"'^CPF-<vt addr range>'"

 

 

Variables:

 

 

• variable text address range = 1 - 4000.

 

Example:

 

 

SEND_COMMAND Remote,"'^CPF-500'"

 

Clears all page flips from the button.

 

 

^DPF

Delete page flips from button if it already exists.

Delete page flips

Syntax:

 

from button if it

"'^DFP-<vt addr range>,<actions>,<page name>'"

already exists

Variable:

 

 

 

 

• variable text address range = 1 - 4000.

 

• actions =

Stan[dardPage] - Flip to standard page

 

 

Prev[iousPage] - Flip to previous page

 

 

Show[Popup] - Show Popup page

 

 

Hide[Popup] - Hide Popup page

 

 

Togg[lePopup] - Toggle popup state

 

 

ClearG[roup] - Clear popup page group from all pages

 

 

ClearP[age] - Clear all popup pages from a page with the

 

 

specified page name

 

 

ClearA[ll] - Clear all popup pages from all pages

 

• page name = 1 - 50 ASCII characters.

 

Example:

 

 

SEND COMMAND Device,"'^DPF-409,Prev'"

 

Deletes the assignment of a button from flipping to a previous page.

 

 

^ENA

Enable or disable buttons with a set variable text range.

Enable or

Syntax:

 

disable buttons

"'^ENA-<vt addr range>,<command value>'"

with a set

Variables:

 

variable text

 

 

 

range

• variable text address range = 1 - 4000.

 

• command value = (0= disable, 1= enable)

 

Example:

 

 

SEND_COMMAND Device,"'^ENA-500.504&510.515,0'"

 

Disables button pushes on buttons with variable text range 500-504 & 510-515.

 

 

 

58

Mio Modero R-4

Page 64
Image 64
AMX Mio Modero R-4 manual Bww, Cpf, Dpf, Ena