Programming the Mio R-4

?TXT

Get the current text information

Get the current text information.

Syntax:

SEND_COMMAND <DEV>,"'?TXT-<vt addr range>,<button states range>,<optional index>'"

Variables:

variable text address range = 1 - 4000.

button states range = 1 - 256 for multi-state buttons

(0 = All states, for General buttons 1 = Off state and 2 = On state).

optional index = This is used if a string was too long to get back in one command. The reply will start at this index.

custom event type = 1001:

Flag - Zero

Value1 - Button state number

Value2 - Actual length of string

Value3 - Index

Text - Text from the button

Text length - Button text length

Example:

SEND COMMAND Device,"'?TXT-529,1'"

Gets the button 'OFF state' text information.

The result sent to the Master would be:

ButtonGet Id = 529 Type = 1001

Flag = 0

VALUE1 = 1

VALUE2 = 14

VALUE3 = 1

TEXT = This is a test

TEXT LENGTH = 14