Programming the Mio R-4

 

? Button Query Commands (Cont.)

 

 

 

 

?BWW

Syntax:

 

Get the current

SEND_COMMAND <DEV>,"'?BWW-<vt addr range>,<button states range>'"

 

word wrap flag

Variables:

 

status

 

• variable text address range = 1 - 4000.

 

 

 

 

• button states range = 1 - 256 for multi-state buttons

 

 

(0 = All states, for General buttons 1 = Off state and 2 = On state).

 

 

• custom event type = 1010:

 

 

Flag - Zero

 

 

Value1 - Button state number

 

 

Value2 - 0 = no word wrap, 1 = word wrap

 

 

Value3 - Zero

 

 

Text - Blank

 

 

Text length - Zero

 

 

Example:

 

 

SEND COMMAND Device,"'?BWW-529,1'"

 

 

Gets the button 'OFF state' word wrap flag status information.

 

 

The result sent to the Master would be:

 

 

ButtonGet Id = 529 Type = 1010

 

 

Flag = 0

 

 

VALUE1 = 1

 

 

VALUE2 = 1

 

 

VALUE3 = 0

 

 

TEXT =

 

 

TEXT LENGTH = 0

 

 

 

 

?FON

Syntax:

 

Get the current

SEND_COMMAND <DEV>,"'?FON-<vt addr range>,<button states range>'"

 

font index

Variables:

 

 

 

 

• variable text address range = 1 - 4000.

 

 

• button states range = 1 - 256 for multi-state buttons

 

 

(0 = All states, for General buttons 1 = Off state and 2 = On state).

 

 

• custom event type = 1007:

 

 

Flag - Zero

 

 

Value1 - Button state number

 

 

Value2 - Font index

 

 

Value3 - Zero

 

 

Text - Blank

 

 

Text length - Zero

 

 

Example:

 

 

SEND COMMAND Device,"'?FON-529,1'"

 

 

Gets the button 'OFF state' font type index information.

 

 

The result sent to the Master would be:

 

 

ButtonGet Id = 529 Type = 1007

 

 

Flag = 0

 

 

VALUE1 = 1

 

 

VALUE2 =72

 

 

VALUE3 = 0

 

 

TEXT =

 

 

TEXT LENGTH = 0

 

 

 

 