Programming the Mio R-4

? Button Query Commands (Cont.)

?TEC

Syntax:

Get the current

SEND_COMMAND <DEV>,"'?TEC-<vt addr range>,<button states range>'"

text effect color

Variables:

 

 

• variable text address range = 1 - 4000.

 

• button states range = 1 - 256 for multi-state buttons

 

(0 = All states, for General buttons 1 = Off state and 2 = On state).

 

• custom event type = 1009:

 

Flag - Zero

 

Value1 - Button state number

 

Value2 - Actual length of string (should be 9)

 

Value3 - Zero

 

Text - Hex encoded color value (ex: #000000FF)

 

Text length - Color name length (should be 9)

 

Example:

 

SEND COMMAND Device,"'?TEC-529,1'"

 

Gets the button 'OFF state' text effect color information.

 

The result sent to the Master would be:

 

ButtonGet Id = 529 Type = 1009

 

Flag = 0

 

VALUE1 = 1

 

VALUE2 = 9

 

VALUE3 = 0

 

TEXT = #5088F2AE

 

TEXT LENGTH = 9

 

 

?TEF

Syntax:

Get the current

SEND_COMMAND <DEV>,"'?TEF-<vt addr range>,<button states range>'"

text effect name

Variables:

 

 

• variable text address range = 1 - 4000.

 

• button states range = 1 - 256 for multi-state buttons

 

(0 = All states, for General buttons 1 = Off state and 2 = On state).

 

• custom event type = 1008:

 

Flag - Zero

 

Value1 - Button state number

 

Value2 - Actual length of string

 

Value3 - Zero

 

Text - String that represents the text effect name

 

Text length - Text effect name length

 

Example:

 

SEND COMMAND Device,"'?TEF-529,1'"

 

Gets the button 'OFF state' text effect name information.

 

The result sent to the Master would be:

 

ButtonGet Id = 529 Type = 1008

 

Flag = 0

 

VALUE1 = 1

 

VALUE2 = 18

 

VALUE3 = 0

 

TEXT = Hard Drop Shadow 3

 

TEXT LENGTH = 18

 

 

72

Mio Modero R-4

Page 78
Image 78
AMX Mio Modero R-4 manual ?Tec, Send Command Device,?TEC-529,1, ?Tef, Send Command Device,?TEF-529,1