AMX Mio Modero R-4 manual Gll, Grd, Gru, Gsc

Models: Mio Modero R-4

1 102
Download 102 pages 12.65 Kb
Page 66
Image 66

Programming the Mio R-4

"^" Button Commands (Cont.)

^GLL

Change the bargraph lower limit.

Change the

Syntax:

bargraph lower

"'^GLL-<vt addr range>,<bargraph low>'"

limit

Variable:

 

 

• variable text address range = 1 - 4000.

 

• bargraph limit range = 1 - 65535 (bargraph lower limit range).

 

Example:

 

SEND_COMMAND Device,"'^GLL-500,150'"

 

Changes the bargraph lower limit to 150.

 

 

^GRD

Change the bargraph ramp-down time in 1/10th of a second.

Change the

Syntax:

bargraph

"'^GRD-<vt addr range>,<bargraph ramp down time>'"

ramp-down time

Variable:

in 1/10th of a

 

second

• variable text address range = 1 - 4000.

 

• bargraph ramp down time = In 1/10th of a second intervals.

 

Example:

 

SEND_COMMAND Device,"'^GRD-500,200'"

 

Changes the bargraph ramp down time to 20 seconds.

 

 

^GRU

Change the bargraph ramp-up time in 1/10th of a second.

Change the

Syntax:

bargraph

"'^GRU-<vt addr range>,<bargraph ramp up time>'"

ramp-up time in

Variable:

1/10th of a

 

second

• variable text address range = 1 - 4000.

 

• bargraph ramp up time = In 1/10th of a second intervals.

 

Example:

 

SEND_COMMAND Device,"'^GRU-500,100'"

 

Changes the bargraph ramp up time to 10 seconds.

 

 

^GSC

Change the bargraph slider color or joystick cursor color. A user can also assign the color

Change the

by Name and R,G,B value (RRGGBB or RRGGBBAA).

Syntax:

bargraph slider

color or joystick

"'^GSC-<vt addr range>,<color value>'"

cursor color

Variable:

 

 

• variable text address range = 1 - 4000.

 

• color value = Refer to theRGB Values for all 88 Basic Colors table on page 35.

 

Example:

 

SEND_COMMAND Device,"'^GSC-500,12'"

 

Changes the bargraph or joystick slider color to Yellow.

 

 

60

Mio Modero R-4

Page 66
Image 66
AMX Mio Modero R-4 manual Gll, Grd, Gru, Gsc