ADSP-2186

TIMING PARAMETERS

Parameter

 

 

 

 

Min

Max

Unit

 

 

 

 

 

 

 

IDMA Read, Long Read Cycle

 

 

 

Timing Requirements:

 

 

 

tIKR

IACK

Low before Start of Read1

0

 

ns

tIRP

Duration of Read1

15

 

ns

Switching Characteristics:

 

 

 

tIKHR

IACK High after Start of Read1

 

15

ns

tIKDS

IAD15–0 Data Setup before

IACK

Low

0.5 tCK – 10

ns

tIKDH

IAD15–0 Data Hold after End of Read2

0

 

ns

tIKDD

IAD15–0 Data Disabled after End of Read2

 

10

ns

tIRDE

IAD15–0 Previous Data Enabled after Start of Read

0

 

ns

tIRDV

IAD15–0 Previous Data Valid after Start of Read

 

15

ns

tIRDH1

IAD15–0 Previous Data Hold after Start of Read (DM/PM1)3

2 tCK – 5

ns

tIRDH2

IAD15–0 Previous Data Hold after Start of Read (PM2)4

tCK

– 5

ns

NOTES

1Start of Read = IS Low and IRD Low.

2End of Read = IS High or IRD High. 3DM read or first half of PM read.

4Second half of PM read.

IACK

tIKHR tIKR

IS

tIRP

IRD

tIRDE

PREVIOUS

IAD 15–0

DATA

tIRDV

tIRDH

tIKDS

READ

DATA

tIKDH

tIKDD

Figure 23. IDMA Read, Long Read Cycle

–26–

REV. 0

Page 26
Image 26
Analog Devices ADSP-2186 specifications Parameter Min Max Unit Idma Read, Long Read Cycle