ADSP-2186

TIMING PARAMETERS

Parameter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Min

Max

Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Memory Read

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Timing Requirements:

 

 

 

tRDD

RD

Low to Data Valid

 

0.5 tCK – 9 + w

ns

tAA

A0–A13, xMS to Data Valid

 

0.75 tCK – 10.5 + w

ns

tRDH

Data Hold from

RD

High

0

 

ns

Switching Characteristics:

 

 

 

tRP

RD Pulse Width

0.5 tCK – 5 + w

 

ns

tCRD

CLKOUT High to

RD

 

Low

0.25 tCK – 5

0.25 tCK + 7

ns

tASR

A0–A13,

xMS

Setup before

RD

Low

0.25 tCK – 6

 

ns

tRDA

A0–A13, xMS Hold after RD Deasserted

0.25 tCK – 3

 

ns

tRWR

RD

High to

RD

or

WR

Low

0.5 tCK – 5

 

ns

w = wait states × tCK.

xMS = PMS, DMS, CMS, IOMS, BMS.

CLKOUT

A0 – A13

DMS, PMS,

BMS, IOMS,

CMS

RD

tASR

tRP

tCRD

D

tRDD

tAA

WR

tRDA

tRWR

tRDH

Figure 17. Memory Read

–20–

REV. 0

Page 20
Image 20
Analog Devices ADSP-2186 specifications Parameter Min Max Unit Memory Read