WPT SEQ

OBS/HLD

WPT SEQ

OBS/HLD

D

ENTER

Approach Examples

Point D (Inbound to OED)

1.As you intercept the 162 inbound a course intercept alert is given. Sequencing is automatically enabled. Turn to intercept the desired course. At 3 nm inbound to OED, the Approach Active annunciator will begin flashing to indicate that approach RAIM prediction is beginning. The transition to approach active is starting.

2.At 2 nm inbound to OED, the CDI sensitivity will begin changing from 1 nm to 0.3 nm full-scale deflection.

3.As you cross OED, the Approach Active annunciator will come on solid to indicate that approach operation is active and you may continue the approach to the MAP (MA14).

Point E (Between OED and MA14)

1.Continue to the missed approach point. Verify that the OBS/HLD and Approach Active annunciators are lighted steady.

2.If you wish to cancel Approach Active, press OBS/HLD. Your Apollo GX will then revert to Approach Transition with 1 nm CDI deflection and a 1 nm RAIM alarm limit.

Point F (Choosing not to land at the MAP)

1.At the Missed Approach Point, if you are not going to land, follow your missed approach clearance. The MAP will remain active and your Apollo GX will continue to provide guidance on the final approach course until you press the OBS/HLD key. The published missed approach instructions say “climbing right turn to 6100’ direct OED VOR and hold.” You will then press the OBS/HLD key as soon as you decide to miss the approach.

2.The CDI will scale out to 1 nm and OED will become the active waypoint. As you reach 6100’, press DIRECT-TOand then press ENTER to establish a direct route to the active waypoint (OED).

9-47