Asante Technologies 100TX Deleting an Alarm, Modifying an Alarm, Enter a number in sec- onds

Models: 100TX 100

1 74
Download 74 pages 27.27 Kb
Page 38
Image 38
The name of the person who defined the alarm entry.

Management

Field

Sampling

Interval

Owner String

Description

The polling interval that determines how often to make the measurement.

The name of the person who defined the alarm entry.

Action

Enter a number (in sec- onds).

Note: The shorter the sampling interval, the more traffic on the net- work.

Enter an eight-byte octet.

Deleting an Alarm

To delete an alarm:

1 Select the alarm entry to be deleted by clicking once on its row in the Alarm Threshold Table.

2

3

4

Click Modify.

The Modify Dialog box appears.

Open the Status drop-down menu and select invalid.

Click Apply.

The alarm is deleted. Click Refresh to view updated information.

Modifying an Alarm

To modify an alarm:

1

2

3

4

Select the alarm entry to be modified by clicking once on its row in the Alarm Threshold Table.

Click Modify.

The Modify Dialog box appears.

Modify the parameters, as desired, following the guide- lines on page 3-25.

Click Apply.

The alarm is modified. Click Refresh to view updated information.

Page 3-26

Page 38
Image 38
Asante Technologies 100TX Deleting an Alarm, Modifying an Alarm, The name of the person who defined the alarm entry