Threshold

Threshold

This menu displays the current alarms that are set and allows alarms to be added or modified.

Alarms can help you locate problems or faults on the network. When you set an alarm threshold for an activity on a hub, you instruct the hub to take a specific action when the value falls above or below the set threshold.

Table 4-11 describes each field in the Threshold menu.

ΔNote: For instructions on using this menu, see “Setting Alarms” on page 3-24.

 

Table 4-11 Threshold Menu

 

 

Field

Description

 

 

Index

Read-only field; displays the number of the alarm

 

entry. This field cannot be modified.

 

 

Status

Configurable field; displays the status of the entry in

 

the table.

 

valid — active entry.

 

invalid — inactive entry (deletes the entry

 

when selected).

 

 

Target Domain

Configurable field; determines the portion of the

 

device for which alarms are being set.

 

port — sets the alarm for a specific port; you

 

must enter the port number in the Target Port

 

field.

 

group — sets the alarm for a specific group;

 

you must enter the group number in the Tar-

 

get Group field.

 

segment0 — sets the alarm for the entire

 

device.

 

 

Target Group

Configurable field; determines the group number for

 

which to set the alarm.

 

Important: This field only needs to be edited if the

 

Target Domain is set to group.

 

 

Target Port

Configurable field; determines the port number for

 

which to set the alarm.

 

Important: This field only needs to be edited if the

 

Target Domain is set to port.

 

 