Menus

Field

Description

 

 

Subject

Configurable field; determines the counter to be

 

polled.

 

readableframes — the total number of good or

 

readable frames (frames without error).

 

frametoolong — the number of frames that

 

were longer than 1,518 bytes.

 

runts — the number of frames that were

 

shorter than 64 bytes.

 

alignmenterrors — the number of frames that

 

were an integral number of octets in length

 

and did not pass the FCS check.

 

fcserrors — the number of frames that failed

 

Cyclic Redundancy Check (CRC).

 

dataratemismatch — the number of errors

 

where the incoming data rate is not within the

 

tolerance level of 10Mhz (+ or - 0.01%).

 

shortevents — the number of data bursts,

 

where data is less than 10 bytes in length.

 

collisions — the total number of collisions.

 

latecollisions — the number of collisions that

 

occurred after the 64-byte collision window.

 

autopartitions — the number of times the port

 

was automatically partitioned in response to

 

31 or more continuous collisions.

 

badframes — the number of invalid frames

 

(including toolong, runts, misaligned, or bad

 

FCS).

 

 

Sample Type

Read-only field; sets a unit of measure for the alarm.

 

Note: This field is always set to eventpersecond and

 

cannot be modified.

 

 

Page 4-14