Chapter 11 Avaya P330 Layer 2 Features

Intermodule Port Redundancy

The intermodule port redundancy feature supports one pair of redundant ports per stack. The secondary port is activated:

when the primary port link is down, or

when the module in the stack holding the primary port has been powered down or removed.

Switching time for intermodule port redundancy is approximately 1 second. Defining intermodule port redundancy on ports with no link causes both ports to be disabled. You should connect the link prior to attempting to define intermodule port redundancy.

Once a port has been designated in a redundancy scheme, either as a primary or a secondary port, it can not be designated in any other redundancy scheme. Intermodule Port Redundancy does not interworks with the Spanning Tree Algorithm.

Port Redundancy CLI Commands

The following table contains a list of the CLI commands for the Redundancy feature. The rules of syntax and output examples are all set out in detail in the P330 Reference Guide.

In order to...

Use the following command...

 

 

 

 

Define or remove port redundancy

set port redundancy

schemes

 

 

 

Enable the defined port

set port redundancy enable

redundancy schemes

 

 

 

Disable the defined port

set port redundancy disable

redundancy schemes

 

 

 

Define the timers that control the

set port redundancy-interval

port redundancy operation

 

 

 

Display information on port

show port redundancy

redundancy schemes.

 

 

 

Define the switch’s unique

set intermodule port redundancy

intermodule redundancy scheme

 

 

 

Clear the intermodule redundancy

set intermodule port redundancy

 

off

 

 

94

Avaya P332G-ML User’s Guide

Page 110
Image 110
Avaya P332G-ML manual Intermodule Port Redundancy, Port Redundancy CLI Commands